Related Experiment Video
Updated: Feb 4, 2026

Author Spotlight: Development and Application of SERS Flexible Substrates Using Synthesized AgNPs
Published on: November 17, 2023
SERS-based quantification of albuminuria in the normal-to-mildly increased range
Andrei Stefancu1, Vlad Moisoiu, Corina Bocsa
1Faculty of Physics, Babeş-Bolyai University, Cluj-Napoca, Romania. nicolae.leopold@phys.ubbcluj.ro.
Abstract:
The lack of an accurate point-of-care detection system for microalbuminuria represents an important unmet medical need that contributes to the morbidity and mortality of patients with kidney diseases. In this proof-of-concept study, we used SERS spectroscopy to detect urinary albumin concentrations in the normal-to-mildly increased albuminuria range, a strategy that could be useful for the early diagnosis of renal impairment due to uncontrolled hypertension, cardiovascular disease or diabetes. We analyzed 27 urine samples by SERS, using iodide-modified silver nanoparticles and we could discriminate between groups with high and low albumin concentrations with an overall accuracy of 89%, 93% and 89%, using principal component analysis-linear discriminant analysis and cut-off values of 3, 6 and 10 μg mL-1 for urinary albumin concentrations, respectively. We achieved a detection limit of 3 μg mL-1 for human serum albumin based on the 1002 cm-1 SERS band, attributed to the ring breathing vibration of phenylalanine. Our detection limit is similar to that of the immunoturbidimetric assays and around one order of magnitude below the detection limit of urinary dipsticks used to detect microalbuminuria. We used principal least squares regression for building a spectral model for quantifying albumin. Using an independent prediction set, the R2 and root mean squared error of prediction between predicted and reference values of human serum albumin concentrations were 0.982 and 2.82, respectively. Here, we show that direct SERS spectroscopy has the sensitivity required for detecting clinically relevant concentrations of urinary albumin, a strategy that could be used in the future for the point-of-care screening of microalbuminuria.
More Related Videos
Related Concept Videos
Variation: Normal Distribution, Range, and Standard Deviation
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Increasing Function
Normal Distribution
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...

