Related Experiment Video
Updated: Feb 4, 2026

An Anatomical Study of Nerves at Risk During Minimally Invasive Hallux Valgus Surgery
Published on: February 17, 2018
Early ileostomy reversal after minimally invasive surgery and ERAS program for mid and low rectal cancer
Corrado Pedrazzani1, Federica Secci2, Eduardo Fernandes3
1Division of General and Hepatobiliary Surgery, Department of Surgical Sciences, Dentistry, Gynecology and Pediatrics, University of Verona Hospital Trust, University of Verona, Verona, Italy. corrado.pedrazzani@univr.it.
Abstract:
Diverting loop ileostomy following low anterior resection (LAR) is known to decrease quality of life and prolongs the return back to patients' baseline activity. The aim of this retrospective study was to explore feasibility and safety of an early ileostomy reversal strategy in a cohort of patients undergoing minimally invasive LAR within an enhanced recovery after surgery (ERAS) program. Prospectively collected data from 15 patients who underwent minimally invasive LAR and diverting ileostomy at the Division of General and Hepatobiliary Surgery, University of Verona Hospital Trust between September 2015 and December 2016 were retrospectively analyzed. Of 15 patients, 10 patients underwent laparoscopic LAR and 5 patients a robot-assisted procedure. Post-operative complications were observed in 5 patients. Four patients suffered Clavien-Dindo grade 1 or 2 complications, and one patient required redo surgery due to bowel obstruction at the ileostomy site (grade 3b). Following ileostomy reversal, 10 out of 15 patients experienced complications. Two patients required redo surgery for bowel obstruction (grade 3b), whilst eight patients suffered grade 1 or 2 complications, being surgical site infection the most frequently observed (6 cases). Despite that, 80% of patients had their ileostomy reversed within 30 days and median time from initial surgery to ileostomy reversal was 22 days (range 10-150). Early ileostomy closure after minimally invasive LAR and ERAS program is feasible although it carries non-negligible risk of severe complications which, however, does not hinder its accomplishment.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Reversible and Irreversible Processes
Diode: Reverse bias
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Modeling of Diode Reverse Characteristics
When a reverse voltage applied to a Zener diode exceeds its breakdown voltage, the diode enters the breakdown region. At this point, the...
Entropy Change in Reversible Processes
The statement can be further generalized to prove that entropy is a state function. Take a cyclic process between any two points on a p-V diagram.

