Related Experiment Video
Updated: Feb 4, 2026

Design and Development of Aptamer–Gold Nanoparticle Based Colorimetric Assays for In-the-field Applications
Published on: June 23, 2016
A test strip for ochratoxin A based on the use of aptamer-modified fluorescence upconversion nanoparticles
Shijia Wu1,2,3, Lihong Liu2, Nuo Duan4
1State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China.
Abstract:
An aptamer-based test strip is described for visual and instrumental determination of the mycotoxin ochratoxin A (OTA). It is based on the use of NaYF4:Yb,Er upconversion nanoparticles (UCNPs) as a label for the aptamer and on the competition between OTA and its complementary sequence for an OTA-specific aptamer. To improve the analytical performance, the optical properties of the UCNPs, the fluidity of the UCNP-aptamer conjugate, and the migration rate on the nitrocellulose membranes were investigated. Under the optimal experimental conditions and by using a 980-nm laser, the relative fluorescence intensity (test line value/control line value) is proportional to the logarithm of the OTA concentration over a range from 5 to 100 ng·mL-1 (R2 = 0.9955). The limit of the detection is 1.86 ng·mL-1. This aptamer based flow assay can be performed within 15 min and has no serious cross-sensitivity to potentially interfering species. It was successfully applied to the determination of OTA in spiked wheat and beer samples. Graphical abstract An aptamer-based upconversion fluorescent strip based on the use of NaYF4:Yb,Er nanoparticles was developed for sensitive detection of Ochratoxin A. The limit of the detection was determined as 1.86 ng·mL-1. The assay can be performed within 15 min, indicating its great potential in point-of-care testing.
More Related Videos
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Modified Boxplots
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...
Base Excision Repair
The first step of...
Antiasthma Drugs: Leukotriene Modifiers
Leukotriene modifiers work through two distinct mechanisms:
Photoluminescence: Fluorescence and Phosphorescence
A pair of electrons in a...
Atomic Fluorescence Spectroscopy

