Resting energy expenditure equations in amyotrophic lateral sclerosis, creation of an ALS-specific equation
Pierre Jésus1, Benoit Marin2, Philippe Fayemendy1
1Nutrition Unit, University Hospital of Limoges, 87000 Limoges, France; INSERM, U1094, Tropical Neuroepidemiology, 87000 Limoges, France; Univ. Limoges, UMR_S 1094, Tropical Neuroepidemiology, Institute of Neuroepidemiology and Tropical Neurology, CNRS FR 3503 GEIST, F-87000 Limoges, France.
Introduction:
Resting energy expenditure (REE) formulas for healthy people (HP) are used to calculate REE (cREE) in amyotrophic lateral sclerosis (ALS) patients. In 50-60% of ALS cases an increase of measured REE (mREE) in indirect calometry (IC) compared to cREE is found. The aims here were (i) to assess the accuracy of cREE assessed using 11 formulas as compared to mREE and (ii) to create (if necessary) a specific cREE formula for ALS patients.
Method:
315 Patients followed in the ALS expert center of Limoges between 1996 and 2014 were included. mREE assessed with IC and cREE calculated with 11 predictive formulas (Harris Benedict (HB) 1919, HB 1984, WSchofield, De Lorenzo, Johnstone, Mifflin, WHO/FAO, Owen, Fleisch, Wang and Rosenbaum) were determined at the time of diagnosis. Fat free mass (FFM) and fat mass (FM) were measured with impedancemetry. A Bland and Altman analysis was carried out. The percentage of accurate prediction ±10% of mREE, and intraclass correlation coefficients (ICC) were calculated. Using a derivation sample, a new REE formula was created using multiple linear regression according to sex, age, FFM and FM. Accuracy of this formula was assessed in a validation sample.
Results:
ICC ranged between 0.60 and 0.71 (moderate agreement), and percentage of accurate prediction between 27.3% and 57.5%. Underestimation was found from 31.7% to 71.4% of cases. According to these unsatisfactory results we created an ALS-specific formula in a derivation sample (130 patients). ICC and percentage of accurate prediction increased in a validation sample (143 patients) to 0.85 (very good agreement) and 65.0% respectively, with 17.5% underestimation.
Conclusion:
REE formulas for HP underestimate REE in ALS patients compared to mREE. Our new ALS-specific formula produced better results than formulas for HP. This formula can be used to estimate REE in ALS patients if IC is not accessible.
Related Concept Videos
The Nernst Equation
The interconnection between standard cell potentials and various thermodynamic parameters such as the standard free energy change ΔG° and equilibrium constant K has been previously explored. For example, a redox reaction involving zinc(II) and tin(II) ions at 1 M concentration with Eºcell = +0.291 V and ΔG° = −56.2 kJ is spontaneous.