Related Experiment Video
Updated: Feb 4, 2026

Wind Tunnel Experiments to Study Chaparral Crown Fires
Published on: November 14, 2017
Retentive force of PEEK secondary crowns on zirconia primary crowns over time
Oliver Schubert1, Josef Reitmaier2, Josef Schweiger3
1Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany. oliver.schubert@med.uni-muenchen.de.
Objectives:
The purpose of the present study was to evaluate the retentive forces of CAD/CAM-fabricated polyetheretherketone (PEEK) secondary crowns on zirconia primary crowns over an artificial aging period representing 10 years of clinical service and compare them to electroformed secondary crowns made from pure gold.
Material And Methods:
Implant-supported zirconia primary crowns (N = 20) were CAD/CAM milled and provided either with electroformed secondary crowns (group ZE; N = 10) or CAD/CAM-fabricated PEEK secondary crowns (group ZP; N = 10). All secondary crowns were attached to a casted tertiary structure to ensure adequate stability. A universal testing machine was used to determine the retentive force values at baseline and after 1, 3, 5, and 10 years of simulated aging in the presence of artificial saliva. Data were analyzed applying Kolmogorov-Smirnov, Kruskal-Wallis, and Mann-Whitney U test. Level of significance was set at p < 0.05.
Results:
Retentive forces were not different for the groups ZE and ZP at baseline (median ZE 2.85 N; ZP 2.8 N; p ≤ 0.218). Because retentive force values changed significantly over simulation time for group ZE (Kruskal-Wallis; p ≤ 0.028), the values between the test groups ZE and ZP differed significantly (Mann-Whitney U) at 5 years (ZE 3.03 N; ZP 2.76 N; p ≤ 0.003) and 10 years (ZE 3.1 N; ZP 2.78 N; p ≤ 0.011).
Conclusions:
PEEK secondary crowns exhibit stable retentive force values over 10 years of simulated aging showing no signs of deterioration while the retentive force values of electroformed secondary crowns increase over time.
Clinical Relevance:
PEEK might be a suitable alternative to proven metallic materials for the fabrication of secondary crowns.
More Related Videos
10:50Assessment of Immunologically Relevant Dynamic Tertiary Structural Features of the HIV-1 V3 Loop Crown R2 Sequence by ab initio Folding
Published on: September 15, 2010
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Related Concept Videos
Crown Ethers
Primary and Secondary Growth in Roots and Shoots
Primary and Secondary Reinforcers
Effective reinforcers for humans vary depending on the individual and the context. Primary reinforcers, such as food, water, sleep, shelter, and pleasure, have inherent value and satisfy basic biological...
Secondary Active Transport
Secondary Active Transport
Secondary Healthcare System