Poly Implant Prothèse silicone breast implants: implant dynamics and capsular contracture
Y Bachour1, Z C M Heinze1, T S Dormaar2
11Department of Plastic, Reconstructive and Hand Surgery, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam, The Netherlands.
Poly Implant Prothèse (PIP) breast implants showed high rates of gel bleeding (42%) and rupture (25%) due to permeable shells. Implant rupture increased capsular contracture risk, while contracture influenced implant volume changes.
Area of Science:
- Plastic Surgery
- Biomaterials Science
- Medical Device Engineering
Background:
- Poly Implant Prothèse (PIP) breast implants were recalled in 2010 due to substandard silicone, leading to increased rupture risks.
- This study investigated the dynamics of PIP implants, focusing on gel bleeding, rupture, and capsular contracture rates and predictors.
Purpose of the Study:
- To analyze the implant dynamics of Poly Implant Prothèse (PIP) breast implants.
- To determine the incidence and risk factors for gel bleeding, rupture, and capsular contracture in PIP implants.
Main Methods:
- Eighty women with 152 PIP implants undergoing reoperation in 2012 were included.
- Demographics and Baker scores were retrospectively collected; pre- and post-operative implant volumes were calculated, and implant integrity was assessed intraoperatively.
Main Results:
- Implants removed after an average of 11 years showed 42% gel bleeding and 25% rupture.
- Gel bleeding correlated with increased post-operative implant volume. Implant rupture significantly increased the risk of capsular contracture.
Conclusions:
- PIP implant shells demonstrated excessive permeability, correlating gel bleeding with post-operative volume increase.
- Implant rupture was identified as a significant risk factor for developing capsular contracture.
More Related Videos
13:35Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
09:59Implantation of Chronic Silicon Probes and Recording of Hippocampal Place Cells in an Enriched Treadmill Apparatus
Published on: October 11, 2017
Related Concept Videos
Dynamic Equilibrium
Equation of Rotational Dynamics
Dynamics of Circular Motion
Any acceleration must be produced by some force. Therefore, any force or combination of forces can cause centripetal acceleration. A few examples include the tension in the rope on a...
Fermi Level Dynamics
Electron affinity in semiconductors refers to the energy gap between the minimum of its conduction band and the vacuum level and it is a critical parameter in determining how easily a semiconductor can accept additional electrons.
The work...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...