Related Experiment Video
Updated: Feb 4, 2026

Intra-Peritoneal Transplantation for Generating Acute Myeloid Leukemia in Mice
Published on: January 6, 2023
High-Risk Acute Promyelocytic Leukemia with Unusual T/Myeloid Immunophenotype Successfully Treated with ATRA and
Zeba N Singh1, Vu H Duong2,3, Rima Koka1
1Department of Pathology, University of Maryland School of Medicine.
Abstract:
We describe two patients with acute promyelocytic leukemia (APL) with an unusual immunophenotype with co-expression of myeloperoxidase (MPO) with cytoplasmic CD3 (cCD3) representing myeloid and T-lineage differentiation. Both harbored FLT3-ITD mutations. One additionally had a deletion in the PML gene affecting the primer binding site, thus limiting measurable residual disease (MRD) analysis during follow-up. Both patients achieved durable remission with all-trans retinoic acid (ATRA) and arsenic trioxide (ATO)-based therapy, thus mitigating the need for repetitive conventional chemotherapy cycles and allogeneic stem cell transplantation. Our report highlights the complexity and challenge of diagnosis and management of APL due to the variant immunophenotype and genetics, and underscores the importance of synthesizing information from all testing modalities. The association of the unusual immunophenotype and FLT3-ITD mutation illustrates the plasticity of the hematopoietic stem cell and the pathobiology of leukemia with mixed lineage or lineage infidelity.
More Related Videos
09:01Flow Cytometry to Estimate Leukemia Stem Cells in Primary Acute Myeloid Leukemia and in Patient-derived-xenografts, at Diagnosis and Follow Up
Published on: March 26, 2018
09:57Comprehensive Protocol to Sample and Process Bone Marrow for Measuring Measurable Residual Disease and Leukemic Stem Cells in Acute Myeloid Leukemia
Published on: March 5, 2018
Related Concept Videos
Unusual Results
According to the range rule of thumb, any value above or below two standard deviations, 2σ from the mean, μ is considered unusual.
Maximum unusual value =...
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Relative Risk
Drug Dosage Regimen: Overview
Typically, the starting dose and dosing interval are guided by the manufacturer's recommendations based on clinical trials conducted during and after drug...
Dosage Regimen: Individualization
Dosage Regimens: Partial Pharmacokinetic Parameters