In vitro bactericidal activity of 0.6% povidone-iodine eye drops formulation
Rosario Musumeci1, Francesco Bandello2, Marianna Martinelli1
1Laboratory of Clinical Microbiology and Virology, Department of Medicine and Surgery, University of Milano-Bicocca, Monza, Italy.
Purpose:
To evaluate the bactericidal activity of a diluted povidone-iodine formulation (0.6%) in comparison with the most used 5% povidone-iodine solution ophthalmic preparation.
Methods:
In vitro bactericidal activity comparison between 0.6% povidone-iodine versus 5% povidone-iodine formulations, against these bacteria: Staphylococcus aureus ATCC 25923, Staphylococcus aureus ATCC 43300, Staphylococcus epidermidis ATCC 12228, linezolid-resistant Staphylococcus epidermidis α99 strain, a clinical isolate, Pseudomonas aeruginosa ATCC 27853, Escherichia coli ATCC 25922.
Results:
About 0.6% povidone-iodine formulation was demonstrated to be faster than 5% povidone-iodine preparation in killing Gram-positive as well as Gram-negative bacteria. Against a linezolid-resistant methicillin-resistant Staphylococcus epidermidis strain, 0.6% povidone-iodine formulation showed the best antiseptic efficacy requirement of 3-log10 reduction in bacterial load, if compared with the 5% povidone-iodine formulation.
Conclusion:
Our investigation has demonstrated that the more diluted 0.6% preparation was more rapidly bactericidal than the 5% povidone-iodine formulation, most probably due to the fact that dilution from 5% to 0.6% increases the amount of free iodine. While our finding must be confirmed by in vivo clinical studies, this fact constitutes an intriguing news for what concerns the use of povidone-iodine eye drops in the ocular surface treatment before intravitreal injections as well as ophthalmic surgery.
Related Concept Videos
Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene
Excess Pressure Inside a Drop and a Bubble
Cartesian Form for Vector Formulation
Resultant Moment: Vector Formulation
The resultant moment of a system of forces can be calculated through vector formulation. For example, if we consider...
Couples: Scalar and Vector Formulation
A couple moment is a rotational force that tends to rotate the steering wheel. The wheel's rotation can either be in a clockwise or anticlockwise direction. The right-hand rule is a helpful method for determining the direction of a couple moment....
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...