Related Experiment Video
Updated: Feb 4, 2026

Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
Brief Report: Safety and Immunogenicity of Rituximab Biosimilar GP 2013 After Switch From Reference Rituximab in
Hans-Peter Tony1, Klaus Krüger2, Stanley B Cohen3
1University of Wuerzburg, Wuerzburg, Germany.
Objective:
Comparable clinical efficacy of the rituximab (RTX) biosimilar GP2013 and reference RTX has been established in blinded randomized trials. However, when switching from a reference biologic to a biosimilar, potential safety implications are often an important consideration. Therefore, the aim of this study was to evaluate the safety of switching from reference RTX to RTX biosimilar GP2013 compared with treatment continuation with reference RTX in patients with rheumatoid arthritis (RA).
Methods:
In this multinational, randomized, double-blind, parallel-group safety study, 107 patients with RA who had previously received treatment (of any duration) with reference RTX as part of routine practice and who required continuation of treatment were randomized to receive either GP2013 or to continue treatment with reference RTX. All patients received a stable dosage of methotrexate and folic acid during the study. Study assessments included the incidence of hypersensitivity, infusion-related and anaphylactic reactions, immunogenicity (antidrug antibodies), and general safety.
Results:
Regardless of whether patients switched to GP2013 or continued treatment with reference RTX, the incidences of hypersensitivity (9.4% and 11.1%, respectively) and infusion-related reactions (11.3% and 18.5%, respectively) were similarly low. Only 1 patient (in the reference RTX group) developed antidrug antibodies to RTX after starting study treatment. No neutralizing antidrug antibodies were observed. Antidrug antibodies were not associated with adverse events (AEs). No clinically meaningful differences in the rate of AEs were observed between treatment groups.
Conclusion:
No safety risks were detected when patients switched from reference RTX to GP2013. The safety profiles of patients in both treatment groups were similar, although the study was not powered for statistical testing of equivalence in safety.
Related Concept Videos
Data Reporting and Recording
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
Survey Safety
Drug Products: Biologics, Biosimilars and Interchangeables
Inertial Frames of Reference
Non-inertial Frames of Reference