Objective:
Quantify physiologically acceptable PICU-discharge vital signs and develop machine learning models to predict these values for individual patients throughout their PICU episode.
Methods:
EMR data from 7256 survivor PICU episodes (5632 patients) collected between 2009 and 2017 at Children's Hospital Los Angeles was analyzed. Each episode contained 375 variables representing physiology, labs, interventions, and drugs. Between medical and physical discharge, when clinicians determined the patient was ready for ICU discharge, they were assumed to be in a physiologically acceptable state space (PASS) for discharge. Each patient's heart rate, systolic blood pressure, diastolic blood pressure in the PASS window were measured and compared to age-normal values, regression-quantified PASS predictions, and recurrent neural network (RNN) PASS predictions made 12 hours after PICU admission.
Results:
Mean absolute errors (MAEs) between individual PASS values and age-normal values (HR: 21.0 bpm; SBP: 10.8 mm Hg; DBP: 10.6 mm Hg) were greater (p < .05) than regression prediction MAEs (HR: 15.4 bpm; SBP: 9.9 mm Hg; DBP: 8.6 mm Hg). The RNN models best approximated individual PASS values (HR: 12.3 bpm; SBP: 7.6 mm Hg; DBP: 7.0 mm Hg).
Conclusions:
The RNN model predictions better approximate patient-specific PASS values than regression and age-normal values.
Related Concept Videos
Discharge Summary Forms
Here's a detailed look at the key components and guidelines for preparing a discharge summary:
Measurement: Derived Units
Measurement: Standard Units
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
RC Circuits: Discharging A Capacitor
Predicting Molecular Geometry