Isolation of High-density Lipoproteins for Non-coding Small RNA Quantification
Published on: November 28, 2016
Characterization of PLAC® tests in the quantization of lipoprotein associated phospholipase A2 for assessment of
1Diazyme Laboratories, Inc, 12889 Gregg Ct., Poway, CA, USA.
Background:
PLAC® mass test (diaDexus, Inc.) does not detect all Lp-PLA2 proteins in the circulation. The total circulating Lp-PLA2 mass can be quantized by using the CHAPS modified PLAC® mass test. To compare the difference of the PLAC® mass, CHAPS modified PLAC® mass and PLAC® activity tests in risk assessment of CVD, the 3 Lp-PLA2 quantization methods were characterized using a collection of serum and plasma from CVD patents and matched non-symptomatic controls. Improvement on risk assessment for ischemic stroke by Lp-PLA2 and lipids were also investigated.
Methods:
Ninety one human sera and plasma from elderly patients with first CVD incidents and 78 matched controls were collected at clinics. Lp-PLA2 was assessed by PLAC® mass, CHAPS modified PLAC® mass and PLAC® activity tests and data were subjected to statistical analyses. Correlation with lipid cholesterols or Apo proteins was compared for all formats of PLAC® tests. Ratios of Lp-PLA2 by different PLAC® tests to different lipids were assessed for synergistic enhancement in the indication of ischemic stroke.
Results:
The PLAC® mass test was superior to other formats of PLAC® tests in the assessment of CVD and is independent of lipids. The Lp-PLA2 by the CHAPS modified PLAC® mass test has no separation between the CVD and control groups.
Conclusions:
Both PLAC® mass and PLAC® activity tests are effective but the CHAPS modified PLAC® mass test has no or less utility in the risk assessment of CVD. The ratio of Lp-PLA2 by either PLAC® mass or PLAC® activity over ApoA1 or (Apo A1 + Apo B) synergistically enhance the risk assessment power for ischemic stroke.
Related Concept Videos
Psychoneuroimmunology: Cardiovascular Disease
A key area of focus in PNI is the relationship between stress and coronary...
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Overview of the Cardiovascular System
Heart
The heart is the central pump of the cardiovascular system that circulates blood throughout the body. It comprises two atria receiving the blood and two ventricles pumping blood out of the heart. Their rhythmic contractions, called heartbeats, ensure that blood flow remains continuous.
Blood Vessels
Blood...