Procedure to Evaluate the Efficiency of Flocculants for the Removal of Dispersed Particles from Plant Extracts
Published on: April 9, 2016
Selection of media for the design of ballasted flocculation processes
Mathieu Lapointe1, Benoit Barbeau1
1Department of Civil, Geological and Mining Engineering, Polytechnique Montreal, Quebec, H3C 3A7, Canada.
Abstract:
Conventional clarification processes imply specific facility footprints that translate into important capital costs. Ballasted flocculation, consisting of injecting ballast medium to increase floc specific gravity and size, is being increasingly used in the water industry owing to its potential for design with very high superficial velocities. However, no systematic approach has yet been proposed to compare and select an appropriate ballast medium with respect to its specific gravity and size. In order to facilitate this procedure, this research project explores the hypothesis that flocculation performance is controlled by the surface area of the medium available for ballasted flocculation. This hypothesis was tested at laboratory scale by evaluating five ballast media with differing specific gravity and size: granular activated carbon, anthracite, silica sand, ilmenite, and magnetite sand having specific gravities of 1.24, 1.45, 2.62, 3.70, and 5.08, respectively. Flocculation kinetics were monitored by measuring floc size through microscopy and with a camera installed directly on the jar-test beaker. Settling performance was monitored using turbidity measurements. This study shows that all ballast media, when expressed as total surface available during flocculation, required similar surface concentrations to achieve settled water turbidity near 1 NTU and lower. In addition, the effects from the ballast media size and specific gravity were lowered for settling time longer than 3 min. Inversely, for settling time of 12 s, larger and denser media produced lower settled water turbidity. For certain applications, lighter ballast media may be more economical because they offer more available surface area for a given mass concentration, hence reducing the amount of ballast media required in the flocculation tank. Finally, the ballast media point of zero charge and shape were not identified as key criteria for ballasted flocculation.
More Related Videos
10:53Concentration of Virus Particles from Environmental Water and Wastewater Samples Using Skimmed Milk Flocculation and Ultrafiltration
Published on: March 17, 2023
08:38Microfluidic Devices for Characterizing Pore-scale Event Processes in Porous Media for Oil Recovery Applications
Published on: January 16, 2018
Related Concept Videos
Group Design
What is Natural Selection?
Microbial Growth Media
Factorial Design
Antibiotic Selection
Frequency-dependent Selection