A Comparison of Simple Analytical Methods for Determination of Fluoride in Microlitre-Volume Plasma Samples
F Vida Zohoori1, Anne Maguire2, E Angeles Martinez-Mier3
1School of Health and Social Care, Teesside University, Middlesbrough, United Kingdom, v.zohoori@tees.ac.uk.
Abstract:
The aim was to compare potential methods for fluoride analysis in microlitre-volume plasma samples containing nano-gram amounts of fluoride. Methods: A group of 4 laboratories analysed a set of standardised biological samples as well as plasma to determine fluoride concentration using 3 methods. In Phase-1, fluoride analysis was carried out using the established hexamethyldisiloxane (HMDS)-diffusion method (1 mL-aliquot/analysis) to obtain preliminary measurement of agreement between the laboratories. In Phase-2, the laboratories analysed the same samples using a micro-diffusion method and known-addition technique with 200 µL-aliquot/analysis. Coefficients of Variation (CVs) and intra-class correlation coefficients (ICCs) were estimated using analysis of variance to evaluate the amount of variation within- and between-laboratories. Based on the results of the Phase-2 analysis, 20 human plasma samples were analysed and compared using the HMDS-diffusion method and known-addition technique in Phase-3. Results: Comparison of Phase-1 results showed no statistically significant difference among the laboratories for the overall data set. The mean between- and within-laboratory CVs and ICCs were < 0.13 and ≥0.99, respectively, indicating very low variability and excellent reliability. In Phase-2, the overall results for between-laboratory variability showed a poor CV (1.16) and ICC (0.44) for the micro-diffusion method, whereas with the known-addition technique the corresponding values were 0.49 and 0.83. Phase-3 results showed no statistically significant difference in fluoride concentrations of the plasma samples measured with HMDS-diffusion method and known- addition technique, with a mean (SE) difference of 0.002 (0.003) µg/mL. In conclusion, the known-addition technique could be a suitable alternative for the measurement of fluoride in plasma with microlitre-volume samples.
Related Concept Videos
Development of Analytical Methods
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Constant Volume Calorimetry
Convenience Sampling Method
Convenience sampling is a non-random method of sample selection; this method selects individuals that are easily accessible and may result in biased data. For example, a marketing...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Sampling Methods: Overview
In analytical chemistry, the choice of...