Related Experiment Video
Updated: Feb 4, 2026

Assessment of Vascular Function in Patients With Chronic Kidney Disease
Published on: June 16, 2014
Polysomnographic Findings in Patients With Chronic Tinnitus
Liane Sousa Teixeira1, Carlos Augusto Costa Oliveira2, Ronaldo Campos Granjeiro3
11 Brasília, Brazil.
Chronic subjective tinnitus significantly disrupts sleep architecture, particularly reducing rapid eye movement (REM) sleep. Patients with tinnitus experience altered REM sleep latency and duration, impacting overall sleep quality.
Area of Science:
- Neurology
- Sleep Medicine
- Otolaryngology
Background:
- Tinnitus is an auditory perception without external stimuli, negatively affecting quality of life, concentration, and emotional stability.
- Chronic tinnitus is associated with sleep disturbances, but its specific impact on sleep architecture requires further investigation.
Purpose of the Study:
- To compare sleep architecture in individuals with and without chronic subjective tinnitus.
- To identify specific sleep stage alterations associated with tinnitus.
Main Methods:
- Observational, noninterventional, prospective study of 50 adults (25 with tinnitus, 25 controls).
- Sleep architecture assessed via polysomnography.
- Standardized questionnaires (Epworth Sleepiness Scale, Tinnitus Handicap Inventory) and visual analog scales were used.
Main Results:
- The tinnitus group exhibited higher mean values in sleep stages 1 and 2 compared to controls.
- The tinnitus group showed lower mean values in stage 3 and rapid eye movement (REM) sleep.
- A statistically significant difference was observed in REM sleep (P = .031), indicating less time spent in REM sleep.
Conclusions:
- Patients with chronic subjective tinnitus demonstrate significant alterations in sleep architecture.
- Specifically, tinnitus is associated with increased REM sleep latency and reduced REM sleep duration.
- These findings highlight the impact of tinnitus on restorative sleep phases.
More Related Videos
03:55Author Spotlight: Enhancing Grasping Abilities for Hemiplegic Patients with Flexible Robotic Limbs
Published on: October 27, 2023
10:15Utilizing Repetitive Transcranial Magnetic Stimulation to Improve Language Function in Stroke Patients with Chronic Non-fluent Aphasia
Published on: July 2, 2013
Related Concept Videos
Finding the Center of Gravity
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Finding Electric Potential From Electric Field
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Finding Volume Using Cross-Sectional Area
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops: