Related Experiment Video
Updated: Feb 4, 2026

Comparing Objective Conjunctival Hyperemia Grading and the Ocular Surface Disease Index Score in Dry Eye Syndrome During COVID-19
Published on: May 25, 2022
An Automated Grading and Diagnosis System for Evaluation of Dry Eye Syndrome
Ayşe Bağbaba1, Baha Şen2, Dursun Delen3
1Computer Engineering Department, Ankara Yıldırım Beyazıt University, Ulus, Ankara, Turkey. aysearslan2491@gmail.com.
Abstract:
This article describes methods used to determine the severity of Dry Eye Syndrome (DES) based on Oxford Grading Schema (OGS) automatically by developing and applying a decider model. The number of dry punctate dots occurred on corneal surface after corneal fluorescein staining can be used as a diagnostic indicator of DES severity according to OGS; however, grading of DES severity exactly by carefully assessing these dots is a rather difficult task for humans. Taking into account that current methods are also subjectively dependent on the perception of the ophtalmologists coupled with the time and resource intensive requirements, enhanced diagnosis techniques would greatly contribute to clinical assessment of DES. Automated grading system proposed in this study utilizes image processing methods in order to provide more objective and reliable diagnostic results for DES. A total of 70 fluorescein-stained cornea images from 20 patients with mild, moderate, or severe DES (labeled by an ophthalmologist in the Keratoconus Center of Yildirim Beyazit University Ataturk Training and Research Hospital) used as the participants for the study. Correlations between the number of dry punctate dots and DES severity levels were determined. When automatically created scores and clinical scores were compared, the following measures were observed: Pearson's correlation value between the two was 0.981; Lin's Concordance Correlation Coefficients (CCC) was 0.980; and 95% confidence interval limites were 0.963 and 0.989. The automated DES grade was estimated from the regression fit and accordingly the unknown grade is calculated with the following formula: Gpred = 1.3244 log(Ndots) - 0.0612. The study has shown the viability and the utility of a highly successful automated DES diagnostic system based on OGS, which can be developed by working on the fluorescein-stained cornea images. Proper implemention of a computationally savvy and highly accurate classification system, can assist investigators to perform more objective and faster DES diagnoses in real-world scenerios.
Related Concept Videos
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation
Irritable Bowel Syndrome (IBS) is classified into subtypes based on the predominant bowel habits as determined by the Bristol Stool Form Scale (BSFS). The subtypes are:
Graded Potential
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...
Types of Aggregate Grading
Well-graded aggregates include a complete range of necessary size fractions that fit together to create a dense matrix with minimal voids, represented by a smooth, continuous gradation curve. This type of grading ensures good...
Dry Friction
To illustrate this concept, imagine a wooden crate resting on a rough, non-uniform horizontal surface. When an external force is applied to...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...

