Comparison of an indirect impression scanning system and two direct intraoral scanning systems in vivo
Patricia Bosniac1, Peter Rehmann1, Bernd Wöstmann2
1Department of Prothodontics, Justus-Liebig-University, Schlangenzahl 14, D-35392, Giessen, Germany.
Objectives:
This in vivo study aimed to compare the marginal discrepancies of zirconia copings manufactured on the basis of two direct intraoral scanning systems and the indirect digitization of a conventional impression.
Materials And Methods:
A total of 63 teeth in 23 patients were prepared to receive full-coverage crowns. Subsequently, these teeth were intraorally scanned using CEREC AC Omnicam and Cara TRIOS and a conventional impression was taken with the scannable PVS Flexitime Fast & Scan. The conventional impression was then extraorally digitized using a D700 laboratory scanner. The zirconia copings were manufactured on the basis of the resulting datasets. Silicone replicas of the copings were produced and sectioned for the measurement of the marginal discrepancy under a digital microscope.
Results:
The statistical analysis showed no significant differences between the two intraoral scanners, the CEREC AC Omnicam (86.09 μm ± 61.46 μm) and the Cara TRIOS (88.95 μm ± 54.46 μm). However, the discrepancies of the zirconia copings obtained from the laboratory scans of conventional impressions (143.29 μm ± 100.71 μm) showed significant differences. Both intraoral scanners achieved a marginal discrepancy below 100 μm, whereas the laboratory scan exhibited considerably higher values.
Conclusions:
The intraoral scanners tested allow for the production of single-tooth-restorations with an adequate marginal fit, whereas the production of restorations on the basis of the scan of a conventional impression led to vast marginal gaps.
Clinical Relevance:
The method of digitizing a conventional impression using a laboratory scanner seemed to have reached its limits in the clinical environment.
Related Concept Videos
Leaky Scanning
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Voltammetric Techniques: Linear-Scan (E vs Time)
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
First Impression
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...