Objectives::
Metal artefacts are highly common in dental CT images because of the high X-ray attenuation of metallic dental fillings and implants. This study presents an evaluation of the virtual monochromatic imaging for metal artefact reduction by a recently introduced dental spectral cone beam CT, which is the first commercial dental spectral CBCT with flat-panel detector.
Methods::
We carried out phantom experiments and clinical trials in this study. In the phantom study, the head phantom with metallic dental fillings and implants of various materials was scanned. Moreover, standard deviation, metal artefact index, and contrast-to-noise ratio were analyzed for fixed region of interest. Patient study included 23 patients with metallic fillings and metal implants. Traditional CT images and virtual monochromatic images were produced in a single scan, ensuring that the comparison can be made within the same patient and same location. Standard deviation and metal artefact index were analyzed for fixed region of interest.
Results::
The phantom study and patient study showed that the metal artefacts caused by metallic dental fillings are well-suppressed by the virtual monochromatic imaging. Moreover, the improvements in virtual monochromatic imaging in terms of image quality are more pronounced for small dental fillings.. The noise increase in image slices without metallic objects is a side-effect of the virtual monochromatic images.
Conclusions::
Virtual monochromatic imaging by spectral cone beam CT reduces the metal artefact and improves the image contrast-to-noise ratio around dental metallic fillings. This kind of imaging would be recommended for patients with dental metallic fillings.
Related Concept Videos
Oxidation-Reduction Reactions
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Alkali Metals
Table 1: Properties of the alkali metals