Related Experiment Video
Updated: Feb 4, 2026

A Micro-CT-based Method for Characterizing Lesions and Locating Electrodes in Small Animal Brains
Published on: November 8, 2018
Simulated Dose Reduction for Abdominal CT With Filtered Back Projection Technique: Effect on Liver Lesion Detection
Tobias Fält1, Marcus Söderberg2, Lisa Hörberg1
11 Department of Translational Medicine, Medical Radiology, Lund University, Skåne University Hospital, Inga Marie Nilssons Gata 49, Malmö 20502, Sweden.
Objective:
Previous studies have shown the possibility to reduce radiation dose in abdominal CT by 25-50% without negatively affecting detection of liver lesions. How radiation dose reduction affects characterization of liver metastases is not as well known. The objective of this study was to investigate how different levels of simulated dose reduction affect the detection and characterization of liver lesions, primarily hypovascular metastases. A secondary objective was to analyze the relationship between the lesion size and contrast-to-noise ratio (CNR) and the detection rate.
Materials And Methods:
Thirty-nine patients (19 with metastases and 20 without) were retrospectively selected. The following radiation dose levels (DLs) were simulated: 100% (reference level), 75%, 50%, and 25%. Five readers were asked to mark liver lesions and rate the probability of malignancy on a 5-grade Likert scale. Noninferiority analysis using the jackknife free-response ROC (JAFROC) method was performed as well as direct comparison of detection rates and grades.
Results:
JAFROC analysis showed noninferior detection and characterization of metastases at DL75 as compared with DL100. However, the number of benign lesions and false-positive localizations rated as "suspected malignancy" was significantly higher at DL75.
Conclusion:
Radiation dose can be reduced by 25% without negatively affecting diagnosis of hypovascular liver metastases. Characterization of benign lesions, however, is impaired at DL75, which may lead to unnecessary follow-up examinations. Finally, increased image noise seems to affect the detection of small lesions to a degree that cannot be explained solely by the reduction in CNR.
Related Concept Videos
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Fischer Projections
Active Filters
Newman Projections
The organic molecules rotate across the single bonds leading to numerous temporary three-dimensional structures of varying energy known as...
Oxidation-Reduction Reactions
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...

