Variation in Platelet Delta Granules Over Time in Young Women Undergoing Evaluation for Heavy Menstrual Bleeding

Gary M Woods1, Natasha Pillay Smiley2, Joseph Stanek3

  • 11 Division of Pediatric Hematology/Oncology, Children's Hospital of the King's Daughters, Norfolk, Virginia.

Insights

Platelet electron microscopy (EM) for delta-granule platelet storage pool deficiency (δ-PSPD) shows significant variability within patients. Caution is advised when using EM alone for δ-PSPD diagnosis due to inconsistent results.

Area of Science:

  • Hematology
  • Platelet Physiology
  • Diagnostic Imaging

Background:

  • Delta-granule platelet storage pool deficiency (δ-PSPD) is a platelet function defect causing bleeding issues.
  • Platelet electron microscopy (EM) is a standard diagnostic tool for δ-PSPD.
  • Intrapatient variability of platelet δ-granule counts by EM is not well understood.

Purpose of the Study:

  • To assess the intrapatient variability of platelet δ-granule numbers using EM.
  • To evaluate the reliability of EM for diagnosing δ-PSPD in young women with heavy menstrual bleeding.

Main Methods:

  • Fifteen young women (11-17 years) with heavy menstrual bleeding underwent serial platelet EM testing over 3 months.
  • Platelet aggregation tests were performed at the initial visit.
  • Analysis focused on average δ-granules per platelet and consistency of results.

Main Results:

  • Nearly half of the patients exhibited substantial variability in platelet EM results.
  • Three patients initially had <2 average δ-granules, with two reverting to ≥2 on follow-up.
  • Platelet aggregation was abnormal in 53% of patients, with no clear correlation to EM findings.

Conclusions:

  • Significant intrapatient variability exists in platelet EM δ-granule counts.
  • EM results for δ-PSPD can be inconsistent, even in serial testing.
  • Providers should exercise caution using EM in isolation for δ-PSPD diagnosis.

Related Concept Videos

The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
1.1K
The Menstrual Cycle01:19

The Menstrual Cycle

The menstrual cycle is a recurrent sequence of changes in the uterine endometrium, specifically its functional layer, the stratum functionalis. This cycle prepares the uterus for potential pregnancy. This cycle typically spans 21–35 days, averaging 28 days, and aligns with the ovarian cycle, regulated by fluctuating levels of ovarian hormones, primarily estrogen and progesterone.
The menstrual phase occurs from days 1 to 5 and involves the shedding of the stratum functionalis, as a...
3.6K
What is Variation?01:14

What is Variation?

Apart from the measures of central tendency, distribution, outliers, and the changing characteristics of data with time, an important characteristic of any data set is its variation or spread. In some data sets, the data values are concentrated closely near the mean; in others, the data values are more widely spread out from the mean.
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
18.5K
The Y-to-Delta Circuit01:19

The Y-to-Delta Circuit

A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
711
The Delta-to-Y Circuit01:16

The Delta-to-Y Circuit

In the delta-wye circuit, the source is delta-connected, while the load is in a wye configuration. This means that the phase voltage of the delta-connected source is equal to the line voltage of the wye-connected load. The connection between two-line currents originates from the delta-connected source. The phase difference in the balanced system allows for calculating one line current given the other, utilizing the positive sequence of phases. In the delta-wye system, the phase currents in the...
870
Bleeding in Fresh Concrete01:22

Bleeding in Fresh Concrete

Bleeding in fresh concrete occurs when water from the mix rises to the surface. This happens because the mix's solid components fail to retain all the water as they settle, leading to separation where water collects at the top. The severity of bleeding can be measured by assessing the total settlement or by noting the decrease in height per unit height of concrete.
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
582