Related Experiment Video
Updated: Feb 4, 2026

Enhanced Oil Recovery using a Combination of Biosurfactants
Published on: June 3, 2022
Young man with severe metabolic acidosis after transformer oil ingestion: a case report
Farah Gul Khan1, Syed Muhammad Zubair2
1Department of Medicine, Aga Khan University Hospital, Karachi, Pakistan. farahgulkhan@yahoo.com.
Background:
Transformer oil is used in oil-filled transformers for its insulating as well as coolant properties. Transformer oil ingestion for attempted suicide is seldom heard of. Our patient's case presented us with a major diagnostic as well as treatment challenge because we encountered such a case for the first time and were totally unaware of the fact that methanol might make up the main component of an aged transformer oil.
Case Presentation:
A 19-year-old Pakistani/Asian man was brought to our hospital with altered sensorium. He was found to have elevated anion gap acidosis, increased osmolal gap, and acute kidney injury. He had no evidence of rhabdomyolysis or hemolysis. Computed tomography of his head showed cerebral edema. He was resuscitated with intravenous fluids and bicarbonate. Three days later, he confessed taking transformer oil with suicidal intention. His clinical picture mimicked acute methanol intoxication. With an initial improvement in his neurological status, he started complaining of constant headache with episodes of agitation and delirium. His renal function continued worsening despite an adequate urine output. He showed a remarkable improvement in his neurological state after just one session of hemodialysis.
Conclusions:
There is evidence that aged transformer oil contains methanol, and a patient who consumes it can present with features mimicking acute methanol intoxication.
More Related Videos
Related Concept Videos
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
What is Metabolism?
Physiology of the Gastrointestinal System I: Ingestion and Propulsion
Bacterial Transformation
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...
Data Reporting and Recording
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...