Related Experiment Video
Updated: Feb 4, 2026

In vivo Imaging of Optic Nerve Fiber Integrity by Contrast-Enhanced MRI in Mice
Published on: July 22, 2014
Optimal contrast-enhanced MRI image thresholding for accurate prediction of ventricular tachycardia using ex-vivo
Dongdong Deng1, Plamen Nikolov1, Hermenegild J Arevalo2
1Institute for Computational Medicine, Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.
Abstract:
Patient specific models created from contrast-enhanced (i.e. late-gadolinium, LGE) MRI images can be used for prediction of reentry location and clinical ablation planning. However, there is still a need for direct and systematic comparison between characteristics of ventricular tachycardia (VT) morphologies predicted in computational models and those acquired in clinical or experimental protocols. In this study, we aimed to: 1) assess the differences in VT morphologies predicted by modeling and recorded in experiments in terms of patterns and location of reentries, earliest and latest activation sites, and cycle lengths; and 2) define the optimal range of infarct tissue threshold values which provide best match between simulation and experimental results. To achieve these goals, we utilized LGE-MRI images from 4 swine hearts with inducible monomorphic VT. The images were segmented to identify non-infarcted myocardium, semi viable gray zone (GZ), and core scar based on pixel intensity. Several models were reconstructed from each LGE-MRI scan, with voxels of intensity between that of non-infarcted myocardium and 20-50% of the maximum intensity (in 10% increments) in the infarct region classified as GZ. VT induction was simulated in each model. Our simulation results showed that using GZ intensity thresholds of 20% or 30% resulted in the best match of simulated propagation patterns and reentry locations with those from the experiment. Overall, we matched 70% (7/10) morphologies for all the hearts. Our simulation shows that MRI-based computational models of hearts with myocardial infarction can accurately reproduce the majority of experimentally recorded post-infarction VTs.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Predicting Molecular Geometry
Self-Evaluation: Self-Enhancement and Self-Verification
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
Optimal Foraging

