Related Experiment Video
Updated: Feb 4, 2026

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Device-Related Thrombus After Left Atrial Appendage Occlusion With the Amulet Device
Michaël Peyrol1, Jennifer Cautela1, Erwan Salaun2
1Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (APHM), Department of Cardiology, Nord Hospital, Chemin des Bourrelly, 13915 Marseille, Cedex, France; MARS Cardio, Mediterranean Association for Research and Studies in Cardiology, Nord Hospital, Chemin des Bourrelly, 13915 Marseille, Cedex, France.
Background:
Left atrial appendage occlusion (LAAO) is increasingly used for stroke prevention in patients with atrial fibrillation who are considered unsuitable for a lifelong oral anticoagulant regimen. Recently, a single-centre study reported device-related thrombus formation in 16.7% of patients treated with the second-generation Amulet device (St. Jude Medical, St. Paul, MN, USA), presenting a potential major safety concern. As "real-world" data on device-related thrombus formation following LAAO with the Amulet occluder are scarce, we aimed to evaluate this outcome in a retrospective registry.
Methods:
Clinical and tranosesophageal echocardiography data after LAAO with the Amulet in consecutive patients from three centres were collated.
Results:
Among 38 patients (mean age 75.8 years), mean (standard deviation) CHA2DS2-VASc and HAS-BLED scores were 4.4 (1.2) and 3.4 (0.9), respectively. All patients underwent successful device placement without procedure-related adverse events. The antithrombotic regimen at discharge consisted of dual antiplatelet therapy (DAPT) in 27 patients (71.1%), single antiplatelet therapy in 10 patients (26.3%), and no antithrombotic therapy in one patient (2.6%). Device-related thrombus was observed in one patient (2.6%) despite DAPT regimen. The outcome of this patient was uncomplicated after adjustment of oral anticoagulant therapy. No patients presented with a thromboembolic event following LAAO during a mean (standard deviation) follow-up of 15 (5) months.
Conclusions:
In this retrospective study, device-related thrombus formation with the second-generation Amulet device was rare and occurred at a rate similar to that of the previous device. Importantly, no patient experienced a device-related thromboembolic event during follow-up. Larger real-life studies are required to confirm the safety profile of this increasingly used device.
Related Concept Videos
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Surface Appendages of Archaea
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Catheterization III: Left Heart Catheterization