Comparison of radiopacity of current restorative CAD/CAM blocks with digital radiography
Mustafa H Atala1, Nagehan Atala2, Elif Yeğin3
1Assistant Professor Faculty of Dentistry, Department of Prosthodontics, Bolu Abant İzzet Baysal University, Bolu, Turkey.
Objective:
While the radiopacity of restorative material affects the radiographic diagnosis of the teeth, there is no data about the radiopacity of current restorative computer-aided design (CAD)/computer-aided manufacturing (CAM) materials. Therefore, the present study compared the radiopacity values of current restorative CAD/CAM blocks to facilitate the material choice within such a wide variety of materials.
Materials And Methods:
Specimens were prepared from 13 different restorative CAD/CAM blocks to compare with enamel and dentin. The specimens placed on the occlusal phosphor plate were imaged with aluminum step wedge and tooth section. The radiopacity values were calculated using the Image J program. The radiopacity values of the specimens were converted to mmAl values with the Curve Expert 1.4 program.
Results:
The difference between the radiopacity values of dentin and e.max CAD was not significant, however, they exhibited a significant difference from the other 14 groups (P < .05). Enamel and Obsidien, Suprinity, and Celtra Duo had greater radiopacity values with significant differences from the other 12 materials whereas the difference within these groups was not significant (P > .05).
Conclusions:
The evaluated restorative CAD/CAM materials have significantly different radiopacity values. Among these permanent restoration blocks, the highest radiopacity value was observed in Celtra Duo, the lowest in Block HC.
Clinical Significance:
Cerasmart, Lava Ultimate, Obsidian, Vita Suprinity, Celtra Duo Blocks have adequate radiopacity for inlay, onlay and crown restorations, however, the use of Vita Enamic, Vita Mark II, GC LRF blocks and the others which have lower radiopacity value than dentin for the same kind of restorations depend on the radiopacity of the luting cement for the purpose of recurrent caries detection.
More Related Videos
07:20Stimulation Location Determination using a 3D Digitizer with High-Definition Transcranial Direct Current Stimulation
Published on: December 20, 2019
12:14CAM-Delam Assay to Score Metastatic Properties by Quantifying Delamination and Invasion Capacity of Cancer Cells
Published on: June 2, 2022
Related Concept Videos
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Restorative Care
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Block Diagram Reduction
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
Electrical Current