Rapid and sensitive detection of Pseudocercospora eumusae pathogen causing eumusae leaf spot disease of banana by

R Thangavelu1, P Ganga Devi1

  • 1ICAR, National Research Centre for Banana, Tiruchirappalli, 620 102 Tamil Nadu India.

3 Biotech
|October 12, 2018
PubMed

Related Concept Videos

RACE - Rapid Amplification of cDNA Ends02:35

RACE - Rapid Amplification of cDNA Ends

Rapid Amplification of cDNA Ends, or RACE, is one of the most effective methods to obtain a full-length cDNA from an mRNA sequence between a known internal region to the unknown sequence at the 5’ or 3’ end. The unknown region is cloned in the cDNA by a gene-specific primer that binds the known end, and a hybrid primer that attaches a predefined anchor sequence to the unknown end of the cDNA. The sequence in between is amplified by PCR with an anchor primer and a gene-specific...
7.3K
Isothermal Processes01:21

Isothermal Processes

A thermodynamic process that occurs at constant temperature is called an isothermal process. Heat slowly flows into the system or out of the system to maintain thermal equilibrium. Processes involving phase changes like water evaporation into steam or freezing water into ice at a constant temperature are examples of Isothermal Processes.
An ideal gas can also undergo isothermal expansion or compression.
For example, consider 1 mole of an ideal gas inside an isolated cylinder at initial volume V...
5.0K
Receptor-mediated Endocytosis01:39

Receptor-mediated Endocytosis

Overview
110.9K
Feedback Loops01:01

Feedback Loops

In most cases, excessive hormone production is prevented by negative feedback—a loop that starts with a stimulus inducing the release of a particular substance, like a hormone, to maintain a certain level before triggering a signal that results in a decrease in further release of the hormone.
64.4K
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
664
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
6.0K