Modified Experimental Conditions for Noise-Induced Hearing Loss in Mice and Assessment of Hearing Function and Outer Hair Cell Damage
Published on: February 10, 2023
The protective effect of metformin against the noise-induced hearing loss
Gülin Gökçen Kesici1, Fatma Ceyda Akın Öcal2, Seren Gülşen Gürgen3
1Department of ENT, Ankara Atatürk Education and Research Hospital, 06800, Ankara, Turkey. gulingokcenmd@gmail.com.
Objective:
To test the protective effect of metformin against noise-induced hearing loss.
Methods:
24 rats were included in the study. The first group was exposed to noise only, the second group took metformin, the third group was exposed to noise and took metformin, and the fourth group was neither exposed to noise nor took metformin as control group. After measurement of baseline DPOAE and ABR of rats, the metformin group and the metformin + noise group received 300 mg/kg/day metformin via gavage for 10 days. On the 11th day, group 1 and group 3 were exposured to white noise at 105 dB SPL for 15 h. After noise exposure, DPOAE and ABR measurements of all rats were repeated on days 1st, 7th, and 21st. At the end of the study, all animals were sacrificed and cochlear tissues were separated for immunohistochemical assessments.
Results:
ABR threshold values and DPAOE measurements of groups 1 and 3 were deteriorated on the 1st day after noise, while deterioration in group 1 continued on 7th and 21st days, but normalized on 7th day in group 3. After immune staining, a significant immunoreaction was observed in the noise group, while the reaction in the noise + metformin group was close to the control group.
Conclusion:
Metformin has a protective effect on noise-induced hearing loss in rats. As a conclusion, it is determined that metformin protects from permanent threshold shift in rats. It can be considered a good alternative for protecting noise-induced hearing loss.
Related Concept Videos
Hearing
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...