An Anatomical Study of Nerves at Risk During Minimally Invasive Hallux Valgus Surgery
Published on: February 17, 2018
[Surgical Devices for Minimally Invasive Cardiac Surgery(MICS)]
1Department of Cardiovascular Surgery, Tokyo Bay Urayasu Ichikawa Medical Center, Urayasu, Japan.
Abstract:
Minimally invasive cardiac surgery(MICS)rapidly has become popular in recent years. To perform meticulous surgical procedures in the limited space, specially designed surgical instruments are very useful. For excellent exposure of the surgical target, thoracoscopic system with high imaging quality such as 4K or 3D HD endoscopy is often used. An articulated rib spreader and/or soft tissue retractor is also useful since those instruments do not interfere with other surgical instruments. A suture catcher is used to pull traction sutures through the chest wall. There are various types of atrial retractor designed for MICS. For fine manipulation in the limited space, long-shafted forceps, needle holders, and scissors are necessary. Those instruments reach deeply located targets and do not interfere surgeon's and endoscopic view or other instruments. A knot pusher is another essential device to tie knots through a small incision. The automatic tying device is available outside the country. For cardiopulmonary bypass, cannulas designed for peripheral access are used. Most of those cannulas have multiple side holes that work well for excellent perfusion and drainage. There are also specially designed aortic cross-clamps. To make surgeons more comfortable and improve quality of MICS, surgical devices for MICS need to be further innovated.
More Related Videos
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...