Related Experiment Video
Updated: Feb 4, 2026

Laboratory-determined Phosphorus Flux from Lake Sediments as a Measure of Internal Phosphorus Loading
Published on: March 6, 2014
Zirconium metal organic frameworks-based DGT technique for in situ measurement of dissolved reactive phosphorus in
Wenxiu Qin1, Yue Gu1, Guozhong Wang1
1Key Laboratory of Materials Physics, Centre for Environmental and Energy Nanomaterials, Anhui Key Laboratory of Nanomaterials and Nanotechnology, CAS Centre for Excellence in Nanoscience, Institute of Solid State Physics, Chinese Academy of Sciences, Hefei, 230031, China.
Abstract:
In an effort to provide early warnings for the occurrence of eutrophication, it is highly desirable to develop an accurate and efficient technique to ensure continuous monitoring of dissolved reactive phosphorus (DRP) in the aquatic environment from the viewpoint of environmental management. Herein, a new diffusive gradient in thin film (DGT) technique was developed and evaluated for in situ measurement of DRP in waters, in which Zr-based metal organic frameworks (MOFs, UiO-66) were utilized as aqueous binding agent (abbreviated as UiO-66 DGT). As expected, the UiO-66 DGT demonstrated high uptake capacity towards phosphorus (20.8 μg P cm-2). Meanwhile, an excellent linearity between the accumulated DRP mass and deployment time over 5 d (R2 = 0.996) was obtained regardless of high or low phosphate solution. In addition, effective diffusion coefficients (D) of DRP increased exponentially with increasing ionic strengths (R2 = 0.99). Based on the rectified D, the performance of the UiO-66 DGT was independent of solution pH (6.5-8.5) and ionic strengths (ranging from 0.01 to 100 mmol L-1). Furthermore, field deployments of the UiO-66 DGT were undertaken in a natural eutrophic lake (Lake Chaohu, China). It was noteworthy that DRP could be continually accumulated by the UiO-66 DGT for more than 14 d and good agreements were obtained between the concentrations measured by DGT (CDGT) and those by ex situ chemical extraction method in solution (Csol), as reflected by CDGT/Csol of 0.9-1.1. In situ determination of DRP speciation was also carried out at different sites across Lake Chaohu. Overall, this study contributed to a better constructing of liquid binding phase DGT for the measurement of DRP in waters, facilitating the widespread application of the UiO-66 DGT as a routine monitoring technique and for large-scale environmental analysis.
More Related Videos
10:13A Technical Guide for Performing Spectroscopic Measurements on Metal-Organic Frameworks
Published on: April 28, 2023
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
The Phosphorus Cycle
Alkali Metals
Table 1: Properties of the alkali metals
Bonding in Metals
Water: A Bronsted-Lowry Acid and Base
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....