Related Experiment Video
Updated: Feb 4, 2026

Full-Endoscopic Surgery for Hypothalamic Hamartoma Resection
Published on: April 12, 2024
Monitoring pulse pressure variation during lung resection surgery
J M Nieves Alonso1, E Alday Muñoz1, A Planas Roca1
1Servicio de Anestesiología, Reanimación y Terapéutica del Dolor, Hospital Universitario de La Princesa, Madrid, España.
Background And Objective:
Although pulse pressure variation (PPV) is an effective dynamic parameter widely used to predict the increase in cardiac output after the administration of fluids in abdominal surgery, its use in thoracic surgery is controversial. A study was designed to describe the behaviour of PPV during lung resection surgery.
Patients And Methods:
A prospective observational study was conducted on adult patients scheduled for lung resection surgery. Patients with bleeding greater than 200cc, or those who required vasopressors during data collection, were excluded. The PPV values were collected during different phases: in bipulmonary ventilation (T1), after the start of single lung ventilation, and the opening of the thorax (T2), at the end of the procedure prior to the restoration of the bipulmonary ventilation (T3), and after the closure of the thorax in bipulmonary ventilation (T4). The correlation coefficient of the PPV values at the different times was calculated.
Results:
The study included 50 consecutive patients. The mean values and standard deviations of PPV in the different phases were: T1, 11.14% (6.67); T2 6.24% (3.21, T3 5.68% (3.19), and T4 7.84% (4.61). The repeated ANOVA measurements found significant differences between the mean values of PPV in the different phases (P<.001). The correlation between the PPV values during T1 and T2 (PPVT1 and PPVT2) was r=0.868 ([P<.001], r2=0.753), while between T3 and T4 (PPVT3 and PPVT4) the correlation was r=0.616 ([P<.001], r2=0.379) between the PPV values in T3 and T4.
Conclusions:
PPV presents a predictable behaviour in the course of lung resection surgery, characterised by a decrease of almost half at the beginning of the unipulmonary ventilation and opening of the thorax. It then remains stable throughout the surgery when there are no changes in the intravascular blood volume.
Related Concept Videos
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Errors occurring during blood pressure monitoring
Several factors...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Pulse
The pulse serves as a clinical...

