Related Experiment Video
Updated: Feb 4, 2026

A Large Animal Model for Acute Kidney Injury by Temporary Bilateral Renal Artery Occlusion
Published on: February 2, 2021
Acute Peritoneal Dialysis System for Neonates with Acute Kidney Injury Requiring Renal Replacement Therapy: A Case
Xiang Ao1, Yong Zhong1, Xiao-He Yu2
1Department of Nephrology, Xiangya Hospital, Central South University, Changsha, Hunan, China.
Background:
Acute kidney injury (AKI) is common in critically ill neonates, and peritoneal dialysis (PD) can be a lifesaving option. In China, however, much of the equipment for PD in neonates is not available. We describe results with a novel system for PD, which has been developed locally to improve access to therapy and care for critically ill neonates requiring PD in China.
Methods:
The system comprises a 14-gauge single-lumen central venous catheter serving as a PD catheter, inserted by Seldinger technique, with an adapted twin bag PD system. Ten neonates with AKI were treated using the novel PD system.
Results:
The 10 patients ranged in age from 1 day to 22 days, with bodyweights between 700 g and 3,300 g. Average time to renal function recovery was between 14 and 96 hours. Complications related to the novel PD system included leak (n = 1), catheter displacement (n = 1), and catheter obstruction (n = 1). There were no complications related to insertion, no cases of peritonitis or exit-site infection, and no subsequent hernias. A comparison of costs indicated that the novel PD system is less expensive than conventional systems involving open insertion of Tenckhoff catheters.
Conclusions:
Peritoneal dialysis using the novel PD system is simple, safe, and effective for suitable neonates with AKI in China.
Related Concept Videos
Acute Kidney Injury I: Introduction
Acute Kidney Injury II: Pathophysiology
Acute Kidney Injury VI: Nursing Management
Acute Kidney Injury V: Interprofessional Care
Continuous Renal Replacement Therapy
Acute Kidney Injury III: Clinical Manifestations