Ding Chen1, Zhangliang Li1,2,3, Jinhai Huang1,2,3
1School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China.
Purpose:
To quantitate lens nuclear opacity using long-range swept-source optical coherence tomography (SS-OCT) images and to evaluate the correlation of this method to Lens Opacities Classification System III (LOCS III) and a Scheimpflug imaging-based grading system (Pentacam Nuclear Stage function; PNS).
Methods:
This study enrolled 120 participants (120 eyes) with age-related nuclear cataracts. The best-corrected visual acuity (BCVA), LOCS III nuclear opalescence (NO) and nuclear colour (NC) were obtained. The nuclear density measured using PNS function (NDPNS) was recorded. Three successive series of long-range SS-OCT images were captured, and the nuclear region was analysed using ImageJ (NIH, Bethesda, Maryland, USA) to generate SS-OCT image-based nuclear density (NDSS-OCT). The repeatability of NDSS-OCT measurement was evaluated using within-subject coefficient of variation (CVw) and intraclass correlation coefficient (ICC). Correlations of NDSS-OCT with NO and NC, BCVA and NDPNS were analysed. According to the integrity of nucleus imaged by Pentacam, patients were divided into two groups, and the parameters were compared between groups.
Results:
The CVw and ICC for NDSS-OCT measurement were 1.5 % and 0.994, respectively. The NDSS-OCT significantly correlated with NO (r=0.831), NC (r=0.873), BCVA (r=0.655) and NDPNS (r=0.891). The NDSS-OCT, NO and NC, and BCVA were significantly different between the two groups.
Conclusion:
Lens nuclear opacity quantitation using long-range SS-OCT images was repeatable and correlated well with LOCS III and PNS function. The Scheimpflug principle had a limitation in imaging dense nucleus. Long-range SS-OCT seems more promising for objectively and quantitatively assessing lens nuclear opacity.
Related Concept Videos
Imaging Studies III: Computed Tomography
Correlations
Sources of Self-Esteem III: Social Comparison
Nuclear Stability
To hold positively charged protons together...
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...