A clinical comparison study of three different methods for treatment of transverse patellar fractures
Depeng Meng1, Peng Xu1, Di Shen1
1Department of Orthopedics, Changzheng Hospital, Second Military Medical University, Shanghai, PR China.
Background:
Tension bands structures are widely used to treat transverse patellar fractures. However, many implants-related complications have been reported. The purpose of this study is to evaluate effects and compare complications of three methods used to treat transverse patellar fractures, including titanium cable tension bands, compression screws with titanium cable cerclage, and X-shaped plating technique.
Methods:
From January 2010 to March 2016, 120 cases of transverse patellar fracture received open reduction and internal fixation with one of three methods: titanium cable tension band (group A), compression screws with titanium cable cerclage (group B), and X-shaped plating technique (group C). Of these, 108 cases were followed for >2 years. Clinical and radiographic data were retrospectively collected and statistically compared.
Results:
Final analysis included 108 patients (n = 38 in group A, 36 in B, and 34 in C). Reduction was satisfactory in all patients after surgery. No significant differences were noted in age, gender, time from injury to surgery, postoperative articular step-off, Lysholm score, and range of motion at 24 months among all groups. At final follow-up, 12 (31.6%) symptomatic implant complications were encountered in group A, along with 6 (16.7%) and 2 (5.9%) in groups B and C, respectively (p < 0.05).
Conclusion:
All three methods could achieve the goal of rigid fixation and early functional rehabilitation. However, the X-plate technique had the lowest risk of symptomatic implant complications and could thus be a safe and effective alternative for internal fixation of transverse patellar fractures.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Speed of a Transverse Wave
One of the key properties of any wave is the wave speed. Light...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Deformations in a Transverse Cross Section
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...