Related Experiment Video
Updated: Feb 4, 2026

Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
[Determination of diethyl phthalate in the air of workplace by gas chromatography]
1School of Medicine and Life Sciences, University of Jinan-Shandong Academy of Medical Sciences, Jinan, Shandong 250062, China.
Abstract:
Objective: To establish a method for the determination of diethyl phthalate by gas chromatography in the air of workplaces. Methods: Diethyl phthalate in the air of workplace was collected throμgh glass fiber filter, eluted with methylbenzene, and detected by gas chromatography coupled with FID detectors. Results: The linear range of diethyl phthalate determined by this method was 14.0~1 400 μg/ml, y=2.09801x-3.66229, and the coefficient correlation was 0.999 99. The detection limit was 1.10 μg/ml, and the minimum detection concentration was 0.18mg/m(3) (collected sample volume was 30 L) . The within-run precisions were 1.04%~2.75%, and the between-run precisions were 0.34%~1.30%. The recovery rates were 98.72%~103.21%, and sampling efficiency was 97.2%~100.0%. The elution efficiencies were 97.25%~98.68%. The samples could be stored at room temperature for 15 days. Conclusion: The indicators established in this study were conformed with the requirements of GBZ/T210.4-2008, "The Guidelines for the Development of Occupational Hygiene Standards Methods Part 4: Determination of Chemical Substances in the Air of Workplaces" . Diethyl phthalate in the workplace air could be rapidly collected, accurate separated and determinated. This method is applicable to the determination of diethyl phthalate in the workplace air.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....