Diagnostic Accuracy of Noncontrast MR Angiography Protocols at 3T for the Detection and Characterization of Lower
Christopher J Hanrahan1, Marc D Lindley1, Michelle Mueller2
1Utah Center for Advanced Imaging Research, University of Utah, 30 North 1900 East, Room 1A71, Salt Lake City, UT 84132.
Purpose:
To compare the diagnostic accuracy of established non-gadolinium (Gd)-enhanced magnetic resonance (MR) angiography protocols with Gd-enhanced MR angiography at 3T for evaluating lower extremity peripheral arterial disease (PAD).
Materials And Methods:
From February 2014 to 2015, 20 patients with PAD and intermittent claudication (16 men; age range, 51-76 y; Fontaine stage II) underwent 3-station (abdominopelvic, thigh, and calf) non-Gd MR angiography and bolus-chase Gd MR angiography protocols performed at 3T (Siemens Tim Trio), including quiescent-interval single-shot (QISS) MR angiography for all 3 stations and a combination of quadruple inversion recovery (QIR) MR angiography for the abdominopelvic station and electrocardiogram-gated fast spin echo (ECG-FSE) MR angiography for the extremities. Two radiologists independently evaluated vessel segments for vascular stenosis, diagnosis confidence, graft presence, and Trans-Atlantic Inter-Society Consensus (TASC) II classification for each station. Diagnostic accuracies and κ agreement were assessed.
Results:
Of 573 vascular segments imaged, 16.9% (97/573, 19/20 patients) demonstrated hemodynamically significant abnormalities. Reader confidence was sufficient for diagnosis in 98% of segments with Gd MR angiography, 93% with QIR/ECG-FSE, and 95% with QISS. Overall reader confidence was higher with QISS than QIR/ECG-FSE within all 3 stations combined (P < .05). With low-confidence segments treated as misdiagnosis, sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and κ agreement for all 3 stations combined were 81.4/87.2/57.0/95.8/86.2%/0.578 for QIR/ECG-FSE and 75.0/90.6/61.6/94.7/88.0%/0.597 for QISS. Using TASC II criteria to assess severity, QISS and QIR/ECG-FSE had no statistical difference in agreement with Gd MR angiography.
Conclusions:
QISS and QIR/ECG-FSE MR angiography protocols demonstrate comparable diagnostic accuracies with high specificity. Either protocol provides an alternative to Gd MR angiography at 3T for patients with PAD.
More Related Videos
08:38Intravital Microscopy of Monocyte Homing and Tumor-Related Angiogenesis in a Murine Model of Peripheral Arterial Disease
Published on: August 26, 2017
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease I: Introduction
Peripheral Artery Disease IV: Nursing Management
Peripheral Artery Disease III: Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management
Coronary Artery Disease I: Introduction
