Aims:
To perform an updated meta-analysis to assess efficacy, safety and technical performance of pulmonary vein isolation using cryoballoon or radiofrequency catheter ablation in patients with paroxysmal or persistent atrial fibrillation.
Methods:
In June 2017, databases and websites were systematically searched for systematic reviews, randomized controlled trials and observational studies reporting data on efficacy, safety and technical performance outcomes at follow-up at least 12 months. Researchers independently assessed records' eligibility, inclusion and methodological quality of included studies.
Results:
Six randomized controlled trials and 25 observational studies - 11 853 patients were included. Studies on paroxysmal atrial fibrillation were 29 and included 11 635 patients. Meta-analysis results showed no difference between cryoballoon and radiofrequency in terms of recurrent atrial fibrillation [risk ratio 1.04, 95% confidence interval (CI) 0.98-1.10] or atrial tachyarrhythmias (risk ratio 1.04, 95% CI 1-1.08) and fluoroscopy time (mean difference -1.92 min, 95% CI -4.89 to 1.05). Cryoballoon ablation was associated with fewer reablations (risk ratio 0.79, 95% CI 0.64-0.98), lower incidence of pericardial effusion (risk ratio 0.52, 95% CI 0.31-0.89) and cardiac tamponade (risk ratio 0.33, 95% CI 0.18-0.62) and shorter total procedural time (mean difference -23.48 min, 95% CI -37.97; -9.02) but with higher incidence of phrenic nerve palsy (risk ratio 5.43, 95% CI 2.67-11.04). Prespecified subgroup analysis confirmed overall results as for freedom from atrial fibrillation and atrial tachyarrhythmias. Only two observational studies included patients with persistent atrial fibrillation, thus hindering any conclusion in this population.
Conclusion:
In patients with paroxysmal atrial fibrillation, cryoballoon and radiofrequency ablation produce similar results in terms of freedom from recurrent atrial fibrillation or atrial tachyarrhythmias but with a different safety profile, being cryoballoon ablation less associated with cardiac complications but more likely to cause phrenic nerve palsy.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Directing Effect of Substituents: meta-Directing Groups
The Sense of Self: Reflected Self-Appraisal and Social Comparison
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences