Related Experiment Video
Updated: Feb 3, 2026

Author Spotlight: Advancing Pathogen Detection and Disease Assessment in Real-Time Using M-ROSE
Published on: March 1, 2024
The use of broad-range bacterial PCR in the diagnosis of infectious diseases: a prospective cohort study
J Tkadlec1, M Peckova2, L Sramkova3
1Department of Medical Microbiology, 2nd Faculty of Medicine, Charles University and Motol University Hospital, Czech Republic.
Objectives:
Broad-range PCR has the potential to detect virtually any bacterial species via amplification and nucleotide sequencing of a DNA region common to all bacteria. We aimed to evaluate its usefulness and clinical relevance when applied to a wide variety of primary sterile materials.
Methods:
A prospective study including 1370 samples (75 heart valves, 151 joint tissue samples, 230 joint aspirates, 848 whole blood samples and 66 culture-negative cerebrospinal fluid samples) were studied by using a commercial PCR system for detecting 16S rDNA (Molzym). The PCR results were compared with culture and were considered to provide added diagnostic value only if the PCR approach revealed new pathogens that were missed by culture.
Results:
The added value of PCR was evident in 173 of 555 PCR-positive samples (0.126; 0.109-0.144 (proportion from all tested samples; 95% confidence interval)), most frequently in examinations of heart valves (0.56; 0.448-0.672) and joint tissue samples (0.219; 0.153-0.284). In contrast, the lowest rate of PCR with added value was noted for blood samples, regardless of the patient cohort they had been drawn from (nononcologic patients from intensive care: 0.065; 0.043-0.087, haematooncologic children: 0.048; 0.027-0.070). Moreover, PCR missed up to 7.1% of blood culture findings (0.071; 0.048-0.095) regarded as clinically relevant, which was the second highest failure rate after joint tissue samples (0.099; 0.052-0.147).
Conclusions:
Broad-range PCR substantially increases detection rate of pathogens, especially from heart valves and joint samples. However, a concurrent risk of false-negative PCR results justifies the need for parallel culture.
Related Concept Videos
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
PCR
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Bacterial Transformation
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...
Variation: Normal Distribution, Range, and Standard Deviation

