Functional, impulse-based quantification of plantar pressure patterns in typical adult gait
Albert H Vette1, Martha Funabashi2, Justin Lewicke3
1Department of Mechanical Engineering, University of Alberta, Donadeo Innovation Centre for Engineering, 9211 - 116 Street NW, Edmonton, Alberta, T6G 1H9, Canada; Glenrose Rehabilitation Hospital, Alberta Health Services, 10230 - 111 Avenue NW, Edmonton, Alberta, T5G 0B7, Canada.
Background:
Dynamic pedobarography is used to measure the change in plantar pressure distribution during gait. Clinical methods of pedobarographic analysis lack, however, a standardized, functional segmentation or require costly motion capture technology and expertise. Furthermore, while commonly used pedobarographic measures are mostly based on peak pressures, progressive foot deformities also depend on the duration the pressure is applied, which can be quantified via impulse measures.
Research Question:
Our objectives were to: (1) develop a standardized method for functionally segmenting pedobarographic data during gait without the need for motion capture; (2) compute pedobarographic measures that are based on each segment's vertical impulse; and (3) obtain a normative set of such pedobarographic measures for non-disabled gait.
Methods:
Pedobarographic data was collected during gait from sixty adults with normal feet. Using the maximum pressure map for each trial, an expert and novice rater independently identified the hallux, heel, medial forefoot, and lateral forefoot and computed nine normalized vertical impulse measures.
Results:
From the computed impulse measures, the Heel-to-Forefoot Balance was 33.3 ± 5.5%, the Medial-Lateral Forefoot Balance (with hallux) 59.2 ± 8.0%, the Medial-Lateral Forefoot Balance (without hallux) 53.5 ± 7.7%, and the Hallux-to-Medial Forefoot Balance 21.0 ± 8.9% (mean ± standard deviation). The intra- and inter-rater reliability ranged between 0.93 and 1.00 and between 0.89 and 0.99, respectively (ICC(2,1)).
Significance:
We developed a simple, stand-alone method for pedobarographic segmentation that is mechanistically linked to relevant anatomical regions of the foot. The normative impulse measures exhibited excellent reliability. This normative dataset is currently used in the clinical assessment of different foot deformities and gait impairments, and in the evaluation of treatment outcomes.
Related Concept Videos
Impulse
Additionally, it can be shown that the...
Impulse Response
Kirchhoff's law forms an input signal equation, with the capacitor's current and voltage providing the output. Substituting the current and dividing by RC yields a differential equation. The output for an impulse input is the impulse...
Typical Model Studies
Adult Stem Cells
Vapor Pressure
Principle of Impulse and Moment