Accuracy of patient-specific instrumentation in total ankle arthroplasty: A comparative study
Guilherme H Saito1, Austin E Sanders1, Martin J O'Malley1
1Foot and Ankle Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY 10021, United States.
Background:
Patient-specific instrumentation (PSI) for TAA is a novel technology with several potential benefits. The primary goal of this study was to compare the use of PSI with the standard referencing guide (SRG) in regards to accuracy of tibial implant positioning. Operative time, fluoroscopy time and accuracy of PSI preoperative reports were also evaluated.
Methods:
A retrospective analysis of 99 patients who underwent a primary TAA with the INFINITY prosthesis (Wright Medical, Memphis, TN) was performed. Patients were divided in two groups based on the type of instrumentation used during the TAA (75 in the PSI group vs 24 in the SRG group). There was no significant difference between groups in regards to age at the time of surgery (P=0.122), sex (P=0.138), number of concomitant procedures performed during surgery (P=0.567) and etiology (P=0.841). However, preoperative deformity was significantly smaller in the PSI group (P=0.002).
Results:
Tibial implant positioning was similar between groups. In the coronal plane, the absolute deviation of the tibial implant from the intended alignment was 1.7±1.4° for the SRG and 1.6±1.2° for PSI (P=0.710). In the sagittal plane, the absolute alignment deviation of the tibial implant was 1.8±1.4° for the SRG and 1.9±1.5° for PSI (P=0.675). Operative time (167 vs 190min, P=0.040) and fluoroscopy time (85 vs 158s, P<0.001) were significantly decreased in the PSI group. The PSI preoperative plan report correctly predicted the implant size in 73% of cases for the tibial component and in 51% of cases for the talar component.
Conclusions:
PSI provided similar tibial component alignment as standard instrumentation. Additionally, PSI preoperative plan reports were poor predictors of implant sizing. Therefore, the final decision should always be based on surgeon's experience in order to prevent errors in implant sizing and positioning.
Level Of Evidence:
Level III, retrospective comparative study.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Ankle Joint
Improving Translational Accuracy
Accuracy and Precision
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...