Related Experiment Video
Updated: Feb 3, 2026

Mesocosm-Scale Constructed Wetland Design for Wastewater Treatment
Published on: May 2, 2025
Variability of release rate of flame retardants in wastewater treatment plants
Jesse Shen1, Shirley Anne Smyth2, Ronald Droste3
1Science and Risk Assessment Directorate, Science and Technology Branch, Environment and Climate Change Canada, 351 Saint Joseph Boulevard, Gatineau, Quebec, K1A 0H3, Canada. jesse.shen@canada.ca.
Abstract:
Information on variability is important in the assessment of the releases and potential risks of brominated flame retardants (BRFs) in the environment, but related data are limited. In this study, two release-characterizing parameters, release fraction to final effluent and influent-biosolids transfer coefficient, were used to quantify releases of five BFRs from eight secondary wastewater treatment plants (WWTPs). The five BFRs are recalcitrant, hydrophobic, and low in volatility. The two parameters for these BFRs were found to vary from day to day and season to season within individual WWTPs as well as from one WWTP to another. These temporal and spatial variations were, however, comparable to each other and both within a factor of 3 above or below the parameter averages. Averages for release fraction were in the range of 0.02-0.29 and those for influent-biosolids transfer coefficient in the range of 3-26 L/g, depending upon a given BFR at a given WWTP. These ranges and the observed factor-3 variability are not only useful for estimating releases of the five BFRs, but more importantly provide read-across data for the assessment of substances with similar physical-chemical properties.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
05:40Comparison of Scale in a Photosynthetic Reactor System for Algal Remediation of Wastewater
Published on: March 6, 2017
Related Concept Videos
Retarders
The function of retarders is to delay the setting of concrete, and this effect can be measured using a penetration test. The retardation process involves adding...
Flame Photometry: Overview
Flame Photometry: Lab
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Plant Hormones