Related Experiment Video
Updated: Feb 3, 2026

UV-Vis Spectroscopic Characterization of Nanomaterials in Aqueous Media
Published on: October 25, 2021
Total coliform inactivation in natural water by UV/H2O2, UV/US, and UV/US/H2O2 systems
Ainhoa Rubio-Clemente1,2,3, Edwin Chica4, Gustavo Peñuela5
1Facultad de Ciencias de la Salud, Universidad Católica de Murcia UCAM, Avenida de los Jerónimos, s/n., Murcia, Spain. ainhoarubioclem@gmail.com.
Abstract:
The presence of pathogens in drinking water can seriously affect human health. Therefore, water disinfection is needed, but conventional processes, such as chlorination, result in the production of dangerous disinfection by-products. In this regard, an alternative solution to tackle the problem of bacterial pollution may be the application of advanced oxidation processes. In this work, the inactivation of total coliforms, naturally present in a Colombian surface water by means of UV/H2O2, UV/US, and the UV/US/H2O2 advanced oxidation processes, was investigated. Under the investigated conditions, complete bacterial inactivation (detection limit equal to 1 CFU 100 mL-1) was found within 5 min of treatment by UV/H2O2 and UV/US/H2O2 systems. UV/US oxidation process also resulted in total bacterial load elimination, but after 15 min of treatment. Bacterial reactivation after 24 h and 48 h in the dark was measured and no subsequent regrowth was observed. This phenomenon could be attributed to the high oxidation capacity of the evaluated oxidation systems. However, the process resulting in the highest oxidation potential at the lowest operating cost, in terms of energy consumption, was UV/H2O2 system. Therefore, UV/H2O2 advanced oxidation system can be used for disinfection purposes, enabling drinking water production meeting the requirements of regulated parameters in terms of water quality, without incurring extremely high energy costs. Nonetheless, further researches are required for minimizing the associated electric costs.
Related Concept Videos
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in...
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
UV–Vis Spectrometers
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

