Quantification of error between the heartbeat intervals measured form photoplethysmogram and electrocardiogram by
Srinivas Kuntamalla1, Ram Gopal Reddy Lekkala2
1a Department of Electronics & Instrumentation Engineering , Kakatiya Institute of Technology & Science , Warangal , India.
Abstract:
Currently, heartbeat intervals required for the analysis of heart rate variability (HRV) are derived from electrocardiogram (ECG). Many investigators have explored the possibility of using photoplethysmography (PPG), for the analysis of HRV. However, all these studies are based on statistical approach and have used the correlation coefficient for the comparison of HRV data obtained using ECG and PPG, which is inappropriate as the causal relationship between the R-peaks in ECG and the systolic peaks in PPG is well known in physiology. In this study, the heart beat intervals measured from PPG, are compared, beat by beat, with the corresponding beat intervals of same cardiac cycle obtained from the synchronously recorded ECG and the differences between them are taken as errors. These errors are verified to exactly match with the variations in the pulse transit times (PTTs), beat by beat. The error in the measurement of heartbeat intervals using PPG is quantified by obtaining the root mean square of the errors associated with each beat interval for a subject. The rms error, which is found to vary between 0.17 and 1.81% across the study group of 42 subjects, can be treated as insignificant, considering the nonstationary character of physiological signals. The errors are compared and interpreted with the variations in PTT. In view of these findings, PPG can be considered as a low cost, safe and more convenient alternative to ECG, as a wearable sensor outside hospital environment, for the analysis of HRV, without compromising on accuracy.
Related Concept Videos
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error