A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
Published on: May 11, 2020
Variability Analysis of Manual and Computer-Assisted Preoperative Thoracic Pedicle Screw Placement Planning
Dejan Knez1, Janez Mohar2, Robert J Cirman2
1Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia.
Study Design:
A comparison among preoperative pedicle screw placement plans, obtained from computed tomography (CT) images manually by two spine surgeons and automatically by a computer-assisted method.
Objective:
To analyze and compare the manual and computer-assisted approach to pedicle screw placement planning in terms of the inter- and intraobserver variability.
Summary Of Background Data:
Several methods for computer-assisted pedicle screw placement planning have been proposed; however, a systematic variability analysis against manual planning has not been performed yet.
Methods:
For 256 pedicle screws, preoperative placement plans were determined manually by two experienced spine surgeons, each independently performing two sets of measurements by using a dedicated software for surgery planning. For the same 256 pedicle screws, preoperative placement plans were also obtained automatically by a computer-assisted method that was based on modeling of the vertebral structures in 3D, which were used to determine the pedicle screw size and insertion trajectory by maximizing its fastening strength through the underlying bone mineral density.
Results:
A total of 1024 manually (2 observers × 2 sets × 256 screws) and 256 automatically (1 computer-assisted method × 256 screws) determined preoperative pedicle screw placement plans were obtained and compared in terms of the inter- and intraobserver variability. A large difference was observed for the pedicle screw sagittal inclination that was, in terms of the mean absolute difference and the corresponding standard deviation, equal to 18.3° ± 7.6° and 12.3° ± 6.5°, respectively for the intraobserver variability of the second observer and for the interobserver variability between the first observer and the computer-assisted method.
Conclusion:
The interobserver variability among the observers and the computer-assisted method is within the intraobserver variability of each observer, which indicates on the potential use of the computer-assisted approach as a useful tool for spine surgery that can be adapted according to the preferences of the surgeon.
Level Of Evidence:
3.
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Thoracic Aorta
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...