Related Experiment Video
Updated: Feb 3, 2026

Using Deuterium Oxide as a Non-Invasive, Non-Lethal Tool for Assessing Body Composition and Water Consumption in Mammals
Published on: February 20, 2020
Reliability and validity of various laboratory methods of body composition assessment in young adults
Matthew M Schubert1,2, Rebekah F Seay2,3, Katie K Spain2,4
1Department of Kinesiology, California State University - San Marcos, San Marcos, CA, USA.
Abstract:
Accurate measures of body composition (BC) are essential for performance and health. In addition to accuracy, BC measures should be practical and be minimally invasive to maximize their utility. The purpose of the present study was to compare the day-to-day variability and validity of four common laboratory-based body composition assessments to a criterion four-compartment model. Dual x-ray absorptiometry (DXA), air displacement plethysmography (BP), multi-frequency bioelectrical impedance (MF-BIA) and underwater weighing (UWW) were performed twice in a sample of 32 young men and women. Participants were assessed in a fasted, euhydrated state 2-7 days apart. All methods were compared to a criterion four-compartment model using BP-derived body volume, DXA-derived bone mineral content and MF-BIA-derived total body water (4CBP ). Additional four-compartment models using UWW- and DXA-derived body volume were also examined (4CUWW ) and (4CDXA ). Validity results were conducted with paired t-tests and Bland-Altman analysis. Reliability was determined using intraclass correlations (ICC), coefficients of variation (CV) and standard error of the measurement (SEM). Validity analysis revealed that all methods overestimated per cent body fat and fat mass, and underestimated fat-free mass when compared with 4CBP , but only DXA and BP were significantly different (P<0·008). All measures were highly reliable across days (ICCs > 0·9, CVs < 12%). Results of the present study indicate that typical laboratory-based methods of body composition are valid and reliable. However, we caution that results should not be translated between methods and assessments should be performed with the same instrument when the goal is to monitor changes in body composition over time.
More Related Videos
Related Concept Videos
Reliability and Validity
Composite Bodies
Composite bodies have widespread applications in mechanical engineering, from automobiles to aircraft to rockets. For example, an automobile wheel comprises...
Composition of Body Fluids
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...

