Suitability of 3D-Printed Root Models for the Development of Transcatheter Aortic Root Repair Technologies
Enrico Ferrari1, Giulia Piazza2, Martin Scoglio2
1From the Cardiac Surgery, Cardiocentro Ticino, Lugano, Switzerland.
Abstract:
Transcatheter aortic root repair (TARR) is still not available because of the complex anatomy. In order to develop future TARR technologies, a human-derived bench test model is required before performing animal tests. For this purpose, we aimed to validate computed tomography (CT)-derived 3D-printed root models for TARR technologies. Four human CT-derived roots were printed using different resins: Visijet M3 Crystal, Photopolymer gel SUP705, Formlabs flexible resin, and Materialise HeartPrint Flex. A stress test was performed using a 26-mm balloon-expandable Sapien valve deployed in aortic position. The too rigid Visijet M3 Crystal was not tested. Among the others, all but one (HeartPrint Flex, Materialise, Leuven, Belgium) ruptured during the test showing low wall resistances. Further tests were then performed in two roots made of HeartPrint Flex resin. The anatomic validation was performed comparing human CT scan-derived 3D reconstructions and CT scan measurements: a mean difference of 0.57 ± 0.4 mm for aortic annulus diameter and for the distance between the aortic annulus and the coronary ostia was measured. Concerning the coronary arteries, they are of paramount importance for new TARR technologies, and therefore, we tested the coronary flows of the HeartPrint Flex root at different pressure levels. At 60 mm Hg, right and left mean adjusted coronary flows were 471 and 663 ml/min; at 80 mm Hg, right and left mean coronary flows were 551 and 777 ml/min; and at 100 mm Hg, right and left mean coronary flows were 625 and 858 ml/min. In our study, 3D-printed root models correlate well with human anatomy and guarantee physiologic coronary flows for TARR technologies.
Related Concept Videos
Primary and Secondary Growth in Roots and Shoots
Root Mean Square
For example, consider the velocity of gas molecules in a container. The gas molecules are moving in different directions, which might impart positive and negative...
Properties of the Root Locus
To determine if a point lies on the root locus, the criterion involves the sum of angles contributed by all poles and zeros to that point. Specifically, this sum must be an odd multiple of 180 degrees. The gain at any point on...
Root-Locus Method
This system can be represented by a block...
Construction of Root Locus
For positive gain values, the root locus exists on the real axis to the left of an odd number of finite open-loop poles or zeros. The root locus starts at the open-loop poles and traces the paths of the closed-loop poles as the gain...
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...