Related Experiment Video
Updated: Feb 3, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Feasibility of Sub-Axial Cervical Laminar Screws, Including C7, in the Indian Population: A Study on 50 Patients
Abhishek Srivastava1, Geetanjali Nanda2, Rajat Mahajan3
1Department of Spine Services, Primus Hospital, New Delhi, India.
Study Design:
Observational study of computed tomography (CT) data.
Purpose:
We performed a CT-based radiographic analysis of sub-axial cervical lamina in the Indian population to assess the feasibility of laminar screws.
Overview Of Literature:
Morphometric studies have been performed for populations of various ethnic groups, but none exist for Indian populations.
Methods:
Cervical spine CT scans of 50 adults with a minimum slice thickness of <2 mm (0.5-2 mm) were obtained from the database of a single center in northern India. Measurements (e.g., length, thickness, and height) were taken in millimeters along the axial, coronal, and sagittal planes. Three measurements were made to assess laminar anatomy, namely, the translaminar/screw length, laminar thickness, and sagittal laminar height.
Results:
The final sample comprised 500 laminae in 50 patients, resulting in 1,500 measurements. The mean translaminar lengths of the C3, C4, C5, C6, and C7 laminae were 19.48 mm, 19.60 mm, 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- , 19.60 , 19.60 mm, 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- mm, 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- , 19.61 , 19.61 mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- mm, 20.49 mm, and 22.85 mm, respectively. The mean thick- , 20.49 , 20.49 mm, and 22.85 mm, respectively. The mean thick- mm, and 22.85 mm, respectively. The mean thick- , and 22.85 mm, respectively. The mean thick , and 22.85 mm, respectively. The mean thicknesses of these cervical laminae were 3.12 mm, 2.62 mm, 2.56 mm, 3.47 mm, and 5.20 mm, respectively. The mean sagittal heights of these laminae were 9.38 mm, 9.80 mm, 10.12 mm, 11.31 mm, and 13.84 mm, respectively. Except for the C7 vertebrae, all other levels had a success rate of <10% in the Indian population using the criteria of a laminar height of at least 9 mm and thickness of 4.5 mm. Limited success was achieved at the C5, C6, and C3 levels.
Conclusions:
To the best of our knowledge, the present study is the only series on the feasibility of laminar screws in the sub-axial cervical spine in the Indian population. We found that Indian patients have smaller anatomical dimensions and thus, are not suitable for laminar screws in the sub-axial cervical spine, barring C7, which is contrary to findings for populations in western and south Asian countries.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Laminar Flow
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
What is Population Genetics?