Related Experiment Video
Updated: Feb 3, 2026

Evaluation of Patients' Posture and Gait Profile After Lumbar Fusion Surgery by Video Rasterstereography and Treadmill Gait Analysis
Published on: March 23, 2019
The validity of using activity monitors to detect step count after lumbar fusion surgery
Sarah J Gilmore1,2, Megan Davidson2, Andrew J Hahne2
1Physiotherapy Department, St Vincent's Private Hospital Melbourne, Fitzroy, VIC, Australia.
Abstract:
Purpose: Measuring step count using activity monitors is an increasingly popular method of quantifying physical activity, however it is unknown whether gait irregularities or the use of gait aids affect the accuracy of these devices. This study evaluates the validity of the ActivPAL3, Fitbit Flex, and Jawbone UP Move activity monitors for measuring step count in hospital inpatients after lumbar fusion.Methods: The ActivPAL3 was tested on the thigh, the Fitbit, and the Jawbone were tested on the wrist and thigh, each monitor was tested 20 times. Validity was examined by calculating the percentage of steps detected by each monitor compared to the criterion measure of observed step count, the Standard Error of Measurement, and the Intraclass Correlation Coefficient.Results: The ActivPAL3 detected 85% (SD 27%) of observed steps. On the wrist, the Fitbit detected 24% (SD 34%) and the Jawbone detected 17% (SD 40%) of observed steps. On the thigh, the Fitbit detected 66% (SD 42%) and the Jawbone detected 22% (SD 35%) of observed steps.Conclusion: The ActivPAL3 activity monitor is a sufficiently valid tool to detect step count immediately after lumbar fusion. Wrist worn monitors are not recommended in this population, particularly with patients using gait aids.Implications for RehabilitationWalking may be quantified using activity monitoring, as both an assessment tool and as an adjunct to treatmentThe ActivPAL3 is sufficiently valid for use after lumbar fusion surgeryThe Fitbit Flex and Jawbone UP Move had low accuracy, particularly when a gait aid was used.
Related Concept Videos
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Reliability and Validity
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch
Therapeutic communication is not the same as social interaction. Social interaction has no goal or purpose and consists of casual information sharing, whereas therapeutic communication has a plan or purpose for the conversation. Therapeutic...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...

