Concepts and terms for dose/volume parameters in carbon-ion radiotherapy: Conclusions of the ULICE taskforce
G Vogin1, A Wambersie2, R Pötter3
1Département de radiothérapie, institut de cancérologie de Lorraine Alexis-Vautrin, 54519 Vandœuvre-lès-Nancy cedex, France; CNRS, UMR 7365, ingénierie moléculaire et physiopathologie articulaire (Imopa), 54505 Vandœuvre-lès-Nancy cedex, France; Université de Lorraine, 54505 Vandoeuvre-lès-Nancy, France.
Purpose:
The Union of Light Ion Centers in Europe (ULICE) program addressed the need for uniting scientific results for carbon-ion radiation therapy obtained by several institutions worldwide in different fields of excellence, and translating them into a real benefit to the community. Particularly, the concepts for dose/volume parameters developed in photon radiotherapy cannot be extrapolated to high linear energy transfer particles.
Methods And Materials:
The ULICE-WP2 taskforce included radiation oncologists involved in carbon-ion radiation therapy and International Commission on Radiation Units and Measurements, radiation biologists, expert physicists in the fields of carbon-ion radiation therapy, microdosimetry, biological modeling and image-guided radiotherapy. Consensual reports emerged from multiple discussions within both the restricted group and the wider ULICE community. Public deliverables were produced and disseminated to the European Commission.
Results:
Here we highlight the disparity in practices between treating centers, then address the main topics to finally elaborate specific recommendations. Although it appears relatively simple to add geometrical margins around the clinical target volume to obtain the planning target volume as performed in photon radiotherapy, this procedure is not appropriate for carbon-ion radiation therapy. Due to the variation of the radiation quality in depth, there is no generic relative biological effectiveness value for carbon-ions outside of an isolated point, for a given fractionation and specific experimental conditions. Absorbed dose and "equieffective dose" for specified conditions must always be reported.
Conclusions:
This work contributed to the development of standard operating procedures for carbon-ion radiation therapy clinical trials. These procedures are now being applied, particularly in the first phase III international, multicenter trial (PHRC Étoile).
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
The Carbon Cycle
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Long-term Depression
Self-Concept
Infancy and Emerging Recognition
During infancy, self-concept is virtually nonexistent. Babies do not distinguish themselves as separate entities and often mistake their...
Common Ion Effect