Related Experiment Video
Updated: Feb 3, 2026

Functional Imaging of Brown Fat in Mice with 18F-FDG micro-PET/CT
Published on: November 23, 2012
Use of 18F-FDG PET/CT texture analysis to diagnose cardiac sarcoidosis
Osamu Manabe1, Hiroshi Ohira2, Kenji Hirata3
1Department of Nuclear Medicine, Hokkaido University Graduate School of Medicine, N15 W7, Kita-Ku, Sapporo, Hokkaido, 0608638, Japan.
Purpose:
18F-fluorodeoxyglocose positron emission tomography (FDG PET) plays a significant role in the diagnosis of cardiac sarcoidosis (CS). Texture analysis is a group of computational methods for evaluating the inhomogeneity among adjacent pixels or voxels. We investigated whether texture analysis applied to myocardial FDG uptake has diagnostic value in patients with CS.
Methods:
Thirty-seven CS patients (CS group), and 52 patients who underwent FDG PET/CT to detect malignant tumors with any FDG cardiac uptake (non-CS group) were studied. A total of 36 texture features from the histogram, gray-level co-occurrence matrix (GLCM), gray-level run length matrix (GLRLM), gray-level zone size matrix (GLZSM) and neighborhood gray-level difference matrix (NGLDM), were computed using polar map images. First, the inter-operator and inter-scan reproducibility of the texture features of the CS group were evaluated. Then, texture features of the patients with CS were compared to those without CS lesions.
Results:
Twenty-eight of the 36 texture features showed high inter-operator reproducibility with intraclass correlation coefficients (ICCs) over 0.80. In addition, 17 of the 36 showed high inter-scan reproducibility with ICCs over 0.80. The SUVmax showed no difference between the CS and non-CS group [7.36 ± 2.77 vs. 8.78 ± 4.65, p = 0.45, area under the curve (AUC) = 0.60]. By contrast, 16 of the 36 texture features could distinguish CS from non-CS grsoup with AUC > 0.80. Multivariate logistic regression analysis after hierarchical clustering concluded that long-run emphasis (LRE; P = 0.0004) and short-run low gray-level emphasis (SRLGE; P = 0.016) were significant independent factors that could distinguish between the CS and non-CS groups. Specifically, LRE was significantly higher in CS than in non-CS (30.1 ± 25.4 vs. 11.4 ± 4.6, P < 0.0001), with high diagnostic ability (AUC = 0.91), and had high inter-operator reproducibility (ICC = 0.98).
Conclusions:
The texture analysis had high inter-operator and high inter-scan reproducibility. Some of texture features showed higher diagnostic value than SUVmax for CS diagnosis. Therefore, texture analysis may have a role in semi-automated systems for diagnosing CS.
Related Concept Videos
Shape and Texture of Coarse Aggregate
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...