Management of Paprosky type three B acetabular defects by custom-made components: early results
Alessandro Aprato1, Matteo Giachino2, Paolo Bedino2
1Orthopaedic Department, Città della Salute e della Scienza, University of Turin, Viale 25 Aprile 137 int 6, 10133, Turin, Italy. ale_aprato@hotmail.com.
Purpose:
Our study aims at the evaluation of the recently introduced Lima Promade custom-made acetabular device for the treatment of complex acetabular Paprosky 3B defects.
Methods:
Between 2016 and 2018, eight patients with major acetabular osteolysis and multiple revisions history were treated with a custom-made implant in a single centre and by a single surgeon. We assessed patients' demographics, peri-operative data, and complications and a specific questionnaire was submitted to the surgeon after each procedure.
Results:
All the devices were correctly positioned. In two over eight cases, a post-operative dislocation occurred, where extensive soft tissue impairment was present. The questionnaire showed a good pre-operative and intra-operative experience of the surgeon.
Conclusions:
The Promade custom-made acetabular system showed encouraging results for complex defects and the entire procedure was positively rated. Further analysis with a higher number of cases and a longer follow-up should be performed for a complete clinical and cost-effective evaluation.
More Related Videos
08:20A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
Published on: March 24, 2019
08:29Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
Published on: January 7, 2019
Related Concept Videos
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and...
Components of Language
Vector Algebra: Method of Components
In many applications, the magnitudes and directions of...
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
Drug Binding to Blood Components
HSA is the most abundant plasma protein and is vital in drug binding. It contains distinct drug-binding sites, with different drugs exhibiting affinity for specific sites. There are three main drug-binding domains for HSA: sites I, II, and III. These domains are...