Effect of polyethylene conformity on total knee arthroplasty early clinical outcomes
Pier Francesco Indelli1,2, Salvatore Risitano3,4, Kimberly E Hall3,4
1Department Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Stanford, USA. pindelli@stanford.edu.
Purpose:
Total knee arthroplasty is a successful procedure in treating subjects with end-stage knee osteoarthritis. The objective of this matched study was to evaluate subjective patient satisfaction and clinical and radiological outcomes in two groups of patients undergoing primary TKA using an identical third-generation design with different conformity in the polyethylene insert.
Methods:
One hundred consecutive patients undergoing TKA because of knee osteoarthritis were randomized in two matched groups. Group A included 50 Posterior-Stabilized (PS) implants, while group B included 50 Medially Congruent (MC) implants. The surgical technique was identical: gap balancing in extension and measured resection in flexion; cruciate ligaments were always removed; the coronal alignment followed the mechanical axis and the tibial slope was set at 3° in the PS group and 5° in the MC. Oxford Knee Score (OKS) and Knee Society Score (KSS) were assessed preoperatively and at 2 year minimum follow-up. Two-sample T test statistical analysis was performed.
Results:
All patients were available at final follow-up: there were no preoperative statistical differences between the two groups in the average preoperative ROM (PS 112°, MC 108°; n.s.), average preoperative KSS (PS 64.4, MC 63.7; n.s.), average preoperative OKS (PS 19.6; MC 19.0; n.s.), and average BMI (PS 34.40, MC 34.60; n.s.). At final follow-up, there were no statistical differences between the two groups in the average OKS (PS 40,5; MC 41.1; n.s.) and in the average KSS (PS 161,5, MC 165,7; n.s.). We found a statistically but not clinically significant difference at final ROM: the average maximum active flexion was 120° in the PS group and 123° in the MC group (s.s.).
Conclusion:
This study evaluated two biomechanically different polyethylene inserts in the same TKA design, showing that reducing the level of intra-articular conformity had minimal effects on PROMs and objective short-term clinical results but a potentially beneficial effect on ROM. This study suggests that, once a satisfactory intra-operative stability is obtained, the minimal level of constraint should be used.
Level Of Evidence:
III.
Related Concept Videos
Conformity
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Conformations of Butane
Predicting Reaction Outcomes
Conformations of Cycloalkanes
Conformations of Cyclohexane
The chair form is the most stable and derives its name from its resemblance to the “easy chair.” In the chair conformation, two carbon atoms are arranged out-of-plane — one above and one below, minimizing the torsional strain. In the chair form, the bond angle is very close to the ideal...