Related Experiment Video
Updated: Feb 3, 2026

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
Controlling deformations of gel-based composites by electromagnetic signals within the GHz frequency range
Oksana Savchak1, Tyler Morrison, Konstantin G Kornev
1Materials Sciences and Engineering, Clemson University, Clemson, SC 29634, USA. okuksen@clemson.edu.
Abstract:
Using theoretical and computational modeling, we focus on dynamics of gels filled with uniformly dispersed ferromagnetic nanoparticles subjected to electromagnetic (EM) irradiation within the GHz frequency range. As a polymer matrix, we choose poly(N-isopropylacrylamide) gel, which has a low critical solution temperature and shrinks upon heating. When these composites are irradiated with a frequency close to the Ferro-Magnetic Resonance (FMR) frequency, the heating rate increases dramatically. The energy dissipation of EM signals within the magnetic nanoparticles results in the heating of the gel matrix. We show that the EM signal causes volume phase transitions, leading to large deformations of the sample for a range of system parameters. We propose a model that accounts for the dynamic coupling between the elastodynamics of the polymer gel and the FMR heating of magnetic nanoparticles. This coupling is nonlinear: when the system is heated, the gel shrinks during the volume phase transition, and the particle concentration increases, which in turn results in an increase of the heating rates as long as the concentration of nanoparticles does not exceed a critical value. We show that the system exhibits high selectivity to the frequency of the incident EM signal and can result in a large mechanical feedback in response to a small change in the applied signal. These results suggest the design of a new class of soft active gel-based materials remotely controlled by low power EM signals within the GHz frequency range.
Related Concept Videos
The Electromagnetic Spectrum
Load-frequency control
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Solution Composition During Acid/Base Titrations
The α0 and α1 values...

